runaway from a propylene hydrogenation reactor
During the start-up of a propylene hydrogenation reactor, very high temperatures were generated in the catalyst bed. At the time, propylene and hydrogen were being fed to the reactor which contained a granular catalyst. The temperature rose rapidly, and the hydrogen supply valve tripped at 176 degrees C. Despite the removal of the reactant supply, the temperature continued to rise to more than 600 degrees C, only stabilizing after the reactor had been isolated and depressurized. It was concluded that the start of the incident was caused by wrongly setting the propylene/ hydrogen ratio as a result of faulty calibration of the flow instruments. This allowed the temperature to rise to the point where spontaneous exothermic polymerization of propylene occurred. Investigation of the incident was hampered by the loss of the relevant instrument record charts.
Event Date
September 12, 1981
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The initial cause of this incident was over-hydrogenation, which in turn generated sufficiently high temperatures to begin polymerisation of propylene.