Small leak from a CGH2 trailer
A driver found a small audible leak coming from the rear of the trailer compartment, while conducting in-trip visual walk-around inspection at a roadside. The driver set up perimeter around trailer using triangles and safety cones, contacted the trailer company to notify the leak and contacted local police department to inform of the situation. The company experts inspected found a leak coming from the neck valve threads one of the ten tubes. They decided to vent to atmosphere the hydrogen contained in that tube, connecting a portable vent stack. After having disabled the leaking valve, the trailer returned to facility.
Event Date
August 18, 2015
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIATING CAUSE was probably the loosening of a threaded connection of a valve, probably due to road travel vibrations. The ROOT CAUSE is not provided, however, an effective design should be able to take into account road vibrations on a road vehicle.