Skip to main content

Small leak from a CGH2 trailer (1145)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Small leak from a CGH2 trailer

A driver found a small audible leak coming from the rear of the trailer compartment, while conducting in-trip visual walk-around inspection at a roadside. The driver set up perimeter around trailer using triangles and safety cones, contacted the trailer company to notify the leak and contacted local police department to inform of the situation. The company experts inspected found a leak coming from the neck valve threads one of the ten tubes. They decided to vent to atmosphere the hydrogen contained in that tube, connecting a portable vent stack. After having disabled the leaking valve, the trailer returned to facility.

Event Date
August 18, 2015
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was probably the loosening of a threaded connection of a valve, probably due to road travel vibrations. The ROOT CAUSE is not provided, however, an effective design should be able to take into account road vibrations on a road vehicle.

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

Threaded Connection

Storage/Process Medium
Storage/Process Quantity
280
Design Pressure
17
Location Type
Location description

DESCRIPTION OF THE UNIT The trailer consisted of 10 tubes. The PHMSA source provides a value of released hydrogen of 11000 GCF (28 kg), which corresponds to the content of one tube. This results slightly lower than the nominal capacity of these tube, declared as 12500 GCF (318 kg)

Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

0

Property Loss (offsite)

0

Lessons Learned

The mitigating measures worked well: (i) the regular inspection by drivers along the route, and (ii) the emergency handling by depressurising the leaking tube and releasing its content to the atmosphere. The loosening of threaded connection due to road vibration is a common glitch. It is however unclear, in this event and similar event, how this could be avoided. Is the root cause related shortcoming when installing / maintaining the connections, or to unexpected road conditions during travel?

Event Nature
Emergency Action

The driver set up perimeter around trailer using triangles and safety cones, and notified local police and the company. The company intervention team decided to depressurise the leaking tube by releasing its content to the atmosphere.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident I-2015090569 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)