Skip to main content

Small release from a LH2 tanker (376)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Small release from a LH2 tanker

A liquid hydrogen tanker was parked at a parking place. The vacuum on the tanker vessel deteriorated causing inner container pressure increase. When the inner container pressure reached the nominal pressure limit, the safety relief valve automatically vented the trailer. The vessel was allowed to vent, to allow to reduce the internal pressure to a value safe for transport back to home terminal. The tanker was taken out of service and vacuum problem repaired.

Event Date
March 13, 1993
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIAL CAUSE was the activation of the pressure relief valve due to increased internal pressure of the cryogenic vessel. The ROOT CAUSE was the reduction of the thermal isolation capacity of the isolation external shell of the vessel, due to a deterioration of the vacuum.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

vent valve

Storage/Process Medium
Storage/Process Quantity
2680
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

384

Property Loss (offsite)

0

Post-event Summary

25 kg of hydrogen were released

Lessons Learned

The safety measures in place worked as expected. Releasing (‘’venting”) hydrogen to reduce internal pressure is a standard procedure when travelling. Usually, drivers are able to monitors vessel pressure by regular inspection and therefore perform a venting before the pressures reach the set value of the pressure relief valve. In this case, probably, the stop at the parking place had been too long to detect early enough the thermal isolation deterioration of the vessel, and avoid the valve activation.

Event Nature
Emergency Action

The vessel was allowed to vent, to allow to reduce the internal pressure to a value safe for transport back to home terminal.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Report I-1993050528 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)