A liquid hydrogen tanker was parked at a parking place. The vacuum on the tanker vessel deteriorated causing inner container pressure increase. When the inner container pressure reached the nominal pressure limit, the safety relief valve automatically vented the trailer. The vessel was allowed to vent, to allow to reduce the internal pressure to a value safe for transport back to home terminal. The tanker was taken out of service and vacuum problem repaired.
Event Date
March 13, 1993
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIAL CAUSE was the activation of the pressure relief valve due to increased internal pressure of the cryogenic vessel. The ROOT CAUSE was the reduction of the thermal isolation capacity of the isolation external shell of the vessel, due to a deterioration of the vacuum.