Skip to main content

Small release from a LH2 tanker due to road vibration (77)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Small release from a LH2 tanker due to road vibration

A liquid hydrogen tanker was driving on a highway, when the driver noticed a vapour plume in his mirror. Driver stopped and found a small amount of vapour coming from the vapour recovery line, which was slightly open. The driver closed the valve tightly and the vapour plume ceased. The valve had opened slightly due road vibration. Since the check at company repair facility did not reveal any problem, the tanker was put back in services.

Event Date
September 3, 1991
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

INITIAL CAUSE was the opening the vapour recovery valve due to vibration. The ROOT CAUSE was a design which did not took into account the whole range of mechanical solicitations which the pressure control system of the trailer could experiment when travelling.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

vapour recovery valve

Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

It is unknown if the tanker was full or empty. The capacity is given in GCF (2005. 2 GCF) , which possibly does not refer to the max load of a LH2 tanker, but to the hydrogen gas left in the tank before venting.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

1

Property Loss (offsite)

0

Post-event Summary

A loss of 100 GCF is reported, which probably corresponds to 0. 3 kg

Lessons Learned

This incident is very similar to other, such as the HIAD_070, which attributed to road vibrations the opening of the vapour return valve.

Event Nature
Emergency Action

The driver closed tighter the valve.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Event incident ID I-1991090457 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996), https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages (accessed September 2024)