The incident occurred at the power generator of a nuclear power plant, in a non-nuclear area of the plant. Although hydrogen was use in the system, it was not affected by the fire. Oil leaked at a…
A catastrophic failure of the low pressure turbine followed by fire and flooding severely damaged the generator. The main turbine automatically tripped due to an erroneous mechanical over speed…
The incident started at the unit removing CO2 from the process gas stream of a hydrocracking facility. (Catalysed Removal of Carbon Dioxide = Catacarb). Localized corrosion caused a pipe to fail and…
A leakage and fire occurred during normal operation at a medium-pressure hydrocracker of a refinery. This unit perform a desulphurisation and a decomposition of heavy gas oil. High-temperature and…
A sudden fire started at the hydrogen compressor of a refinery's hydrocracking unit.
The event occurred at a plant for the production of ethylene, and affected the unit for the hydrogenation of pyrolysis gasoline. During a shutdown operation of the hydrogenation plant, the…
This incident occurred at a unit designed to convert heavy oil residues into refined products. It involved a fluidized bed reactor and the related hydrogen supply system serving the optimisation…
A fire occurred in a hydrogen and catalyst loading lines of heavy oil unit. The most likely cause was that a hydrogen purge pipeline failed allowing hydrogen to escape. This mixed with hot oil…
A fire occurred at a refinery hydrocracker plant involving a gauge glass and hydrogen gas oil.
The explosion occurred at the hydro-deoxygenation unit of a renewable fuels facility. Part of this unit is a furnace aiming at pre-heating renewable feedstock, recycled renewable diesel, and…
When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…
A hydrogen leak occurred from a low temperature valve on an acetic acid plant. The leak ignited and the resulting fire burned for about an hour. There was considerable media attention, particularly…
Hydrogen line at ammonia plant sprang a leak which ignited. Fire put out immediately causing no damage.
The incident occurred at the direct desulfurization unit of heavy oil. A 130×90 mm oval opening occurred in the bypass pipe of the hydrogen sulphide absorption tower for the circulating gas, at a…
The explosion occurred during preparatory work to start a compressor that supplies hydrogen gas to a heavy oil direct desulfurization unit. The inspection cover of the crank case came off, injuring…
This incident occurred at the storage system of a hydrogen refuelling station during an inspection. The inspection consisted in the visual inspection of individual pressure vessels of the storage…
At a nuclear power plant, a fire occurred in the station's hydrogen storage facility while the plant was operating at 100% power. The fire was reported to the control room by a non-licensed operator…
A fire occurred on top of a vent stack attached to a LH2 vessel. The ignition source was unknown but electrical storms in the vicinity may have been responsible. The flame was extinguished by…
A fire at the exit of the vent line occurred when filling a tube trailer. An employee suspected a flame at the outlet of the hydrogen venting line during the filling of a trailer. , by sawing the air…
A tube trailer was returning to the basis after having delivered compressed hydrogen to a customer site. The vehicle was operated by two drivers taking turns in driving. While traveling on a highway,…
Lightning caused fires at a plant near Hamburg after igniting a hydrogen mixture release through a ventilation pipe
The ignition of a hydrogen leak occurred at a semitrailer connected to a pressure reducing station, while waiting a transfer. The alert was given by personnel of the company cafeteria located nearby.…
This incident occurred at a at an electronics plant. While transferring of hydrogen from a compressed hydrogen tube trailer to stationary cylinder banks, a leak developed on the transfer hose and…
A LH2 trailer was delivering at a customer location. The LH2 transfer had just been terminated and the driver was ready to depressurise the trailer to remove the hose. When he started to open the…
During the preparation for a liquid hydrogen transfer from a tanker to a stationary storage system, the safety valve opened and the gas ignited. The incident occurred when a pressure build-up was…
This incident occurred at CVD (coating vapour deposition) equipment. During operation, a vacuum pump for air discharging was turned on and by mistake silane and hydrogen gases were allowed to flow…
This incident occurred during the delivery of a hydrogen gas container to a customer site. When a worker turned the protective cap of the container, the valve handle turned together with the…
A truck loaded with 22 hydrogen cylinders pallets (370 litres each) was traveling on a national highway. While stopped at a traffic light, it was rear-ended by a large truck which damaged the…
Near the end of the process of filling a gaseous hydrogen tube trailer at a liquid hydrogen trans-filling station, a safety pressure-relief device (PRD) rupture disc on one of the tube trailers ten…
A compressed hydrogen tube trailer was fully loaded and parked in the sun. The heat caused a pressure build-up, so that a burst disc failed prematurely venting hydrogen, which ignited. 13,360 cu…