HIAD Events

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.



A common vent system was used to connect vent lines from liquid hydrogen storage vessels to the vent stack (which was lit flaring the gas). Low order detonations were observed around the vent…

Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…
The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…

The incident occurred when filling a gaseous tube trailer from a liquid hydrogen stationary storage system. The liquid hydrogen cryogenic pump shaft malfunctioning caused a series of explosions…

Workers were connecting a compressed hydrogen cylinder, when a release of hydrogen occurred within a safety-box for flammable gases (a safety cabinet). During the emergency response procedures, the…

During the J-2 engine testing program, the engine start tank was pressurised. The pressure raised to an excess of 1500 psi (ca. 105 bar). The venting of the tank was attempted but remained…

The failure of a high pressure hydrogen-based synthetic gas feed line to the ammonia converter produced a sudden explosion followed by a severe fire. One of the operators was fatally injured. The…

A steel hydrogen pipeline failed with a circumferential rupture, at a location where a leak had been already detected and repaired. The leak was discovered during a one-call response for planned…

During a test of an 8 foot scale tank loaded with LH2, the tank burst at 77 psi (ca. 5. 3 bar) destroying the test installation. No fire or explosion occurred and the area control was successfully…

A tank of liquefied hydrogen felt down in a chemical plant. The tank, containing 100 m³ of liquid hydrogen, was installed on a concrete plate, which failed. The hydrogen started leaking from the…
The incident happened in an ammonia plant, on the pipe leading hot synthesis gas (syngas) from the synthesis convertor to the first heat exchanger. The pipe cracked, releasing the syngas which did…

Following loading of propellant run tanks, the insulation jacket (filled with perlite) on the conmon vent and pressurisation line for the LH2 storage tank burst. [Ordin, NASA (1974)]

A dual phase hydrogen tanker was expected to refill the storage of a refuelling station for buses. Due to the failure of the a bolt of the tanker pump, the refuelling could not take place. This…

This incident consisted in the dropping of a gas cylinder and the release of its content due to stress corrosion

A driver of a fuel cells vehicle terminated the refuelling and drove away without disconnecting the fueling hose from its vehicle. The breakaway of the fueling hose was supposed to open, but did…

A collision between two vehicles occurred at the corner of two streets. One vehicle was a fuel cells and hydrogen vehicle (FCEV), the other was a conventional one. Its driver incorrectly did not…

Leaking hydrogen ignited a fire that burned several hours at an oil refinery.
An operator had just replaced the ignition port cover on a hydrochloric acid plant burner. Normal start-up was continued by closing the drain valve in the product run off line and opening the…

The fire occurred at the turbine-generator unit of a power plant. A first hydrogen leakage took place from a 4 bolt flange. It ignited producing a small but intense flame, causing further hydrogen…

Hydrogen fire in the compressor-turbine chamber of a power plant. The hydrogen leaked from the generator terminal bushing into unventilated terminal segregated bulbar ducting (this is a duct used…

At a rocket engine testing facility, a combustion experiment of the pre-burner (gas generator for driving the turbopump) was being conducted, before testing the turbopump. The pre-burner is the…

The incident occurred during the filling of six bundles of compressed hydrogen cylinders by means of a compressor. Each bundle consisted of 16 cylinders of 40-liter each. When approaching the…

This incident occurred at an aromatics manufacturing plant. A staff member patrolling the plant heard a strange noise and rushed to the site, where he discovered a hole in a pipe, from which hydrogen…
Fire in an ammonia plant A fire broke out in the hydrogen section of ammonia plant.
The explosion and fire happened in a diesel hydro-treatment unit used to desulphurise raw diesel be means of hydrogen. The facility was expected to begin full commercial operations later in 2020.
The process unit affected by the incident was a two-step production, consisting of i) hydrogenation of phenyl acetyl carbinol with benzyl amine in a isopropyl alcohol/water mixture by means of a…
The explosion occurred at a hydrogen fuel plant mainly serving hydrogen forklift fleets. The explosion damaged several nearby homes and could be felt nearly 10 miles away. Police and firefighters…
Two successive fires broke out in an interval of few minutes in four cells in the electrolysis room of a chlorine production plant. The technicians brought the fire under control using the fire…
Chlorine was released in the liquefaction unit of a chlorine electrolysis plant, due to the rupture of a pipe. During the re-start phase of an electrolysis workshop in a chemical plant, chlorine (Cl2…
The incident occurred at the recycle hydrogen compressor of a hydro-desulphurisation unit. The compressor was equipped with a suction rectifier. The drainpipe of this rectifier had been corroded…