Skip to main content

FCEV driving away with the dispenser hose (706)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

FCEV driving away with the dispenser hose

A driver of a fuel cells vehicle terminated the refuelling and drove away without disconnecting the fueling hose from its vehicle. The breakaway of the fueling hose was supposed to open, but did not. The receptacle fitting sheared off the vehicle. The hydrogen contained in the hose between the dispenser shutoff valve and the vehicle check valve was released. [H2TOOLS]

Event Date
February 24, 2009
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

The INITIATING CAUSE was the tearing of the hose and the braking of the receptacle fitting on the vehicle. The ROOT CAUSE was the error of the driver which forgot to disconnect the hose from the vehicle. CONTRIBUTING CAUSE was the fact that the breakaway system, designed to mitigate the consequences of these cases, did not operate as from design. Tests of the breakaway, performed after event, showed that the breakaway operated at 210 lbs (95 kg), which was above the design value of 133 lbs (60 kg). This was very probable not a manufacturing error, but an installation error. It is further unclear who was supposed to detect this mishaps: could the station have performed regular check?

Facility Information
Application Type
Application
FCEV
Specific Application Supply Chain Stage
Components Involved

breakway, nozzle, receptacle, check valve

Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Events in database H2TOOLS https://h2tools. org/lessons/hydrogen-fueling-dispenser-nozzle-drive-away (accessed December 2025)