The incident occurred in the hydrogen sulphide absorption tower of the kerosene desulphurisation unit of a refinery. The hydrogen leaked from the liquid level gauge and ignited causing a fire. The…
The incident occurred at a university facility, in the premises of a spin-off company. A worker was checking the hydrogen pressure by opening the main valve on a hydrogen cylinder, when hydrogen…
The event occurred when attempting to replace a rupture disk in a LH2 vessel. Hydrogen gas was released and ignited. In fighting the fire, liquid nitrogen was sprayed onto a second LH2 vessel…
A fire in a first stage 'pygas' (pyrolysis of gasoline) hydrogenation of a naphtha cracker was caused by escape of a mixture of gasoline, hydrogen and nickel catalyst through a crack in…
At a chemical processing plant, a release of pressurised hydrogen gas resulted in an explosion and fire injuring lightly three workers and causing damage to plant. The incident occurred during the…
A tube ruptured in the charge heater ('fired heater') of a desulphurisation reactor due to a blockage caused by accelerated coking. Flames spread over an area of some 100 feet outward…
During simultaneous hydrogen venting operations of two hydrogen trailers adjacent to one another, hydrogen was ignited at one, and then the fire ignited the hydrogen venting from the other trailer…
While welding cable suspended over stainless steel H2 instrument line, two holes were burned through tubing. A hissing sound was heard and operator closed a valve. In feeling for gas leak which…
This incident occurred a product purge vessel flange during planned maintenance activities on a chemical plant. The vessel had the function to collect unreacted gases from a polyethylene…
While a LH2 barge was being disconnected from dock, a flash occurred in the vent stack. No damage occurred but potential existed for major damage. [Ordin, NASA (1974)]
The incident occurred at the hydrocracker unit of a refinery. A mixture of hydrogen and hydrocarbon gas was accidentally released. The flammable gas formed a vapour cloud that ignited, resulting…
Hydrogen was accidentally released into the compressor room of a hydrogen refuelling station. The fixed gas detector in the compressor room issued a value of 48% vol. of he Low FLammability Level,…
A hydrogen explosion occurred in a 5-tonne stainless steel pressure vessel, while two electro-polisher workers where electropolishing internal surfaces. The cause is believed to be the build-up…