Hydrogen as carrier gas was provided to a reactor gas chromatograph by several compressed hydrogen bottles. The bottles emptied rapidly, but the loss of carrier gas could only be detected when the…

The leak occurred at an heat exchanger of the hydro-isomerisation unit of a refinery. Following the observation of a pressure drop between two heat exchangers, controls were carried out on site. A…
The event occurred in a desulphurisation unit for heavy oil (hydro-cracking, Isomax process). The hydrogen released from one of the heat exchangers where the feed gases are pre-heated by the reactor…
An explosion took place at the hydrodesulphurisation unit of a refinery's crude oil. A leak occurred on suction line of a hydrogen compressor used for the re-circulation of the hydrogen required for…

The burst disc activated prematurely on a small hydrogen tube trailer. The pressure at which the activation occurred was between 80 and 100 bar (1200 and 1500 psig). The design activation pressure…

Alarm received by firefighters around midnight by a resident who heard abnormal noise under the Beaumont Bridge while walking his dog. Perimeter of security set up very quickly with isolation of the…

A hydrogen detector located above the hydrogenation reactor tripped in a pharmaceutical plant. The internal emergency plan was activated and the personnel evacuated. The operator did not notice…

The release occurred during refuelling of the mobile storage system. This operation was part of a series of tests aiming at verifying the tightness of the system. When opening a valve to connect…

While travelling to deliver liquid hydrogen to a customer, a tanker experienced an increase of the internal pressure of the cargo tank. The drivers pulled off the road and at that moment the…

An explosion occurred at a hydrogen boiler of a chemical manufacturing plant producing hydrogen gas and other substances. A potential flow restriction in the feed line to a hydrogen-fired boiler…

Test facility H2 vent line exploded destroying about 150 feet of line. The flare stack was on at the time. [Ordin, NASA (1974)]

A leak occurred at a dispenser hose of a hydrogen refuelling station. On the day of the accident six FCVs had already been filled. Four minutes after the start of the filling of a seventh vehicle,…

During a transfer of liquid hydrogen from a commercial tanker to a stationary receiving vessel, a leak developed in the bayonet fitting at trailer-vessel connection. The leak produced a hydrogen…

A leak developed on a main connector to a pallet consisting of 12 hydrogen bottles, which had not been re-tightened for a few weeks. The alarm, at at 5% of the LEL, went off , with automatic call…

A tube trailer carrying compressed hydrogen was travelling along a city road, when the drivers heard an abnormal sound from behind. They stopped and discovered that hydrogen was leaking from the…

A tube trailer carrying compressed hydrogen was travelling on a highway, when the drivers heard suddenly heard the sound of leaking gas. They stopped and discovered that that gas was escaping from…

A large hydrogen gas leak from a dewar resulted when bolts holding fitting the top of the tank was loosened. The fitting contained instruments. On loosening the third bolt, hydrogen gas excaped…

The accident occurred during the filling of hydrogen into a fuel cell vehicle (FCV) at a hydrogen station. The gas detector in the dispenser detected a leak, and the equipment was shut down. A…

The accident occurred at a mobile hydrogen station during a fuelling test for a fuel cell vehicle. The day before, the gas detector in the dispenser detected a leak and the equipment was shut down…

A hydrogen leak occurred during refuelling of a fuel cell-powered lift truck. The forklift was depowered. This was the first refuelling after the replacement of the in-tank shutoff solenoid valve…