Skip to main content

Leak from a CGH2 tube trailer (288)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Leak from a CGH2 tube trailer

A tube trailer carrying compressed hydrogen was travelling along a city road, when the drivers heard an abnormal sound from behind. They stopped and discovered that hydrogen was leaking from the threaded joint of a pipe connecting all the tubes to the manifold. They tightened the joint, but the leak did not stop, therefore it was decided to transfer hydrogen to another tube trailer. The reason of the leak was the O-ring of the joint, which did not fit properly. All tube trailers of the same type were modified by installing a valve to each of the tubes.

Event Date
July 18, 1975
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was a defective O-ring causing a leak on a joint. According to the KHK report, the was an inspection failure, which had not been able to identify the wrong O-ring and the ensure tightness the joint before departure. Since the leak was heard only when travelling, road vibration could have been a contributing factor. Since there was no possibility to isolate the tubes from the general manifold, the fundamental ROOT CAUSE is a shortcoming in design, which did not take into account all possible accidental scenarios.

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

O-ring, threaded joint

Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

There were 22 long tubes on the trailer

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Post-event Summary

Since the O-ring was defective and therewas no possibility to isolate the tubes from the common manifold, it was decided to transfer hydrogen to another tube trailer.

Event Nature
Emergency Action

The drivers tightened the joint, but the leak did not stop, therefore it was decided to transfer hydrogen to another tube trailer.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association): https://www. khk. or. jp/public_information/incident_investigation/hpg_incident/incident_db. html (accessed May 2025)