Leak from a CGH2 tube trailer
A tube trailer carrying compressed hydrogen was travelling on a highway, when the drivers heard suddenly heard the sound of leaking gas. They stopped and discovered that that gas was escaping from the fusible plug of one of the cartridges, so traffic was restricted. The KHK report does not provide information on if and how the leak was stopped, and on the reasons for the failure. Information on how the emergency was handled is also missing.
Event Date
October 3, 1975
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIATING CAUSE was the opening of the thermally-activated pressure relief device (TPRD), expected to activate in case of temperature increases. Nothing is known on the reason. Since no pressure anomaly was reported, it is plausible to assume that the TPRD failed pre-maturely due to material defect. The KHK report attributed the ROOT CAUSE to “inspection failure”, without however explaining why the inspection failed.