The incident occurred when refuelling with hydrogen a fuel cell forklift. The hydrogen was provided by a mobile refuelling station. The filling of a second forklift of the day had just begun, when…

The incident occurred at a hydrogen compression facility, due to a leaking fitting a the pressure relief fitting. The hydrogen was released through the pressure relief inertised line. It ignited…

This incident occurred on a high-pressure hydrogen compressor part of the hydrogen production and storage unit of a testing laboratory. While in operation, a hydrogen gas detector installed above…

This near miss occurred at an airport's hydrogen refilling station. At 7:35, a hydrogen leak was detected by hearing whistles in the near of a pipe. The operators warned the airport firefighters ten…

This incident event consists in two leaks occurred in the same week on a hydrogen compressor of a hydrogen refuelling station. After filling a fuel cell vehicle (FCV) with hydrogen at a compressed…

In 1990 the Space Shuttle fleet was grounded for several months by an elusive hydrogen leak occurring during the procedure of fuelling of the liquid hydrogen tank of a space shuttle. The Columbia…

The safety disc failed during unloading from a liquid hydrogen tanker. The release of cryogenic hydrogen resulted in fracturing a section of the vent pipe. [Ordin, NASA (1974)]

A liquid hydrogen leak occurred at the aerospace company (high Tier Seveso). The facility is specialised in production and handling of cryogenic propellants for engines of space vehicles. A 53 m³…

A liquid hydrogen tanker (with a water capacity of 2000 l) was passing a highway interchange, when the safety valve of the tank activated, releasing hydrogen gas. The drivers stopped first on the…

A 9000 gal (34 m3) LH2 storage tank exploded during repair of the vent stack. Few days before the explosion, the tank had been filled with LH2, but later on the hydrogen released and ignited at the…

While on a highway, the driver of a liquid hydrogen tanker was notified that vapour was coming out of the back of the trailer. The driver pulled into a safe haven to investigate. After opening the…

Excessive delay in trip resulted in over-pressure on the liquid hydrogen tank, requiring manual venting. This resulted in releasing of 2750 cu ft of hydrogen [Zalosh and Short, 1978]

The drivers failed to lower the internal pressure of a liquid hydrogen tanker before leaving plant. Therefore they had to stop en route and vent 4000 scf of hydrogen. [Zalosh and Short, 1978]

A liquid hydrogen tanker was returning empty to the base, when a pressure build-up forced the drivers to perform a manual venting. [Zalosh and Short, 1978]

The drivers failed to stabilise the tank pressure after having delivered the liquid hydrogen. Therefore they had to stop and perform a manual vent on journey back to the base. [Zalosh and Short,…

Before loading it with liquid hydrogen, the cyrogenic tank had been purged with nitrogen for maintenance work. After the loading, the drivers failed to stabilise the internal pressure of the tank,…

The pressure building valve opened due to vibration from the road, causing the build-up of the internal pressure. The drivers performed a hydrogen venting and re-sealed the valve. [Zalosh and…

A pressure build-up in the tank of a liquid hyrogen tanker caused the drivers to vent 6000 cu ft of hydrogen to reduce the pressure. [Zalosh and Short, 1978]

Pressure buildup in tank was manually vented by driver releasing 1000 cu ft [Zalosh and Short, 1978]

The tank of a liquid hydrogen tanker was manually vented prematurely on its empty return trip. 9,000 cu ft werereleased [Zalosh and Short, 1978]