A compressed hydrogen container was being filled at a refuelling station. The container was belonging to trailer and consisted in a bundle of tubes connected via piping to a manifold and filling…
A hydrogen compressor had been shut down for repairs and was being put back into service when the explosion occurred, causing damage . The compressor was equipped with interchangeable in take and…
An explosion of hydrogen gas occurred on a test bench at a factory manufacturing rocket engins. The effect was perceived several kilometres away. The explosion was caused by the release of 8 kg of…
While preparations were being made for a LH2 turbopump test, an explosion occurred above the test cell. Major damage was caused throughout the test facility. A short duration fire caused minor…
The incident occurred when filling a gaseous tube trailer from a liquid hydrogen stationary storage system. The liquid hydrogen cryogenic pump shaft malfunctioning caused a series of explosions…
During the J-2 engine testing program, the engine start tank was pressurised. The pressure raised to an excess of 1500 psi (ca. 105 bar). The venting of the tank was attempted but remained…
A steel hydrogen pipeline failed with a circumferential rupture, at a location where a leak had been already detected and repaired. The leak was discovered during a one-call response for planned…
Following loading of propellant run tanks, the insulation jacket (filled with perlite) on the conmon vent and pressurisation line for the LH2 storage tank burst. [Ordin, NASA (1974)]
The incident occurred during the filling of six bundles of compressed hydrogen cylinders by means of a compressor. Each bundle consisted of 16 cylinders of 40-liter each. When approaching the…
A hydrogen leak occurred at the connection between a temperature measuring sleeve and a flange on the cleaning tower of a fertilizers plant (approximately 70% hydrogen, 21% nitrogen and the rest…
This incident occurred at the fired heater of a non-further specified reactor of a refinery (probably a hydro-desulphurisation unit). A tube of the fired box failed releasing a mixture of hydrogen…
The explosion occurred at the hydro-deoxygenation unit of a renewable fuels facility. Part of this unit is a furnace aiming at pre-heating renewable feedstock, recycled renewable diesel, and…
This incident occurred at the storage system of a hydrogen refuelling station during an inspection. The inspection consisted in the visual inspection of individual pressure vessels of the storage…