HIAD Facility - Application Type: Petrochemical Industry


The explosion occurred when a spark from welding equipment ignited flammable vapours from a 415,000-gallon (ca. 1. 5 million of litres) sulphuric acid storage tank at the refinery. The investigation…
The incident occurred at the hydrocracker unit, which was being shut down for maintenance and the reactor was in a hydrogen purge cycle. A hydrogen gas line failed at a weld. The line was at 3000 psi…
A hydrogen leak occurred on the hydrogen line of a hydro-desulphurisation unit, followed by ignition . The failure was located on a supply manifold of the unit at a support beam. The unit was shut…
Three workers were working in the sulphur recovery unit (SRU), trying to restore the hydrogen flow. The workers were trying to isolate the cause of a flow problem: hydrogen was entering the…
The regular maintenance of the hydrogen production equipment had been completed and the plant was about to start up. At this point, fluid mainly composed of hydrogen was sent via a pipe to the…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line affected…
A hot oil line (8-inch) in the hydro-desulphurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343°C sprayed across the roadway into the hydrogen units where ignition occurred…
The release occurred on a pipeline inside a steam cracking unit located between two hydrogenation units. The gaseous mixture transported through this line (2" diameter, 30 bar, 40°C) was composed of…
The leak occurred at an heat exchanger of the hydro-isomerisation unit of a refinery. Following the observation of a pressure drop between two heat exchangers, controls were carried out on site. A…
The event occurred in a desulphurisation unit for heavy oil (hydro-cracking, Isomax process). The hydrogen released from one of the heat exchangers where the feed gases are pre-heated by the reactor…
An explosion took place at the hydrodesulphurisation unit of a refinery's crude oil. A leak occurred on suction line of a hydrogen compressor used for the re-circulation of the hydrogen required for…
The charge pump on a hydro-desulphuriser unit tripped. The charge flow control valve then opened wide on low flow. The high pressure hydrogen supply to the unit flowed backwards through a faulty non…
A leak occurred on a relief valve of a high pressure hydrogen storage tank. No explosion or fire occurred.
The incident occurred during the start-up after a routine repair of the refinery's heavy oil hydrodesulfurization system. A valve at the inlet pipe of a high-temperature and high-pressure separation…
This event regards the degradation of steels used in the heat-exchangers of a reformer of a refinery. An inspection by non-destructive ultrasonic techniques revealed material degradation of the steel…
An operator noted a loose tube sheet flange stud on a high temperature, high pressure heat exchanger in an hydrodealkylation unit. The stud was found to be cracked through. Analysis proved to be made…
The incident occurred during a temporary shutdown of the distillate hydro-treatment unit. The crude oil distillation units main column overhead product was pumped to a gasoline storage tank via the…

A fire broke out at a pipe of the hydrogen production unit, belonging to the steam methane reformer part of the fluidised catalytic cracking (FCC) plant. The fire occurred when personnel of a…

A series of explosions at an oil refinery reformer unit caused by a rupture to an 8 inch naphtha and hydrogen feed pipe. Fire officials cited higher than normal line pressures just before the blast.…
The utility production facilities (electricity, water, air, and steam) at a refinery were isolated from the power grid and switched to two turbine generators in anticipation of a storm. However, at 9…