HIAD Facility - Application Type: Petrochemical Industry


An explosion, followed by a fire, happened in an oven belonging to the hydro-treatment unit. Following a shutdown, the tube, containing only gaseous products and hydrogen, had been affected by…
The leak occurred on a process pipe of a pressurized at 17 bar and located 3. 5 m from the ground The gaseous mixture composed of hydrogen, methane and hydrogen sulphide (density: 0. 6) was released…
An operator on patrol discovered a flame coming from the heat exchanger flange of a gasoline hydrodesulphurisation plant and reported it. The plant was immediately shut down. An investigation…

A mixture of hydrogen and diesel leaked and ignited on a desulphurisation unit of a refinery. The emergency plan was initiated few minutes later. The unit was shut down and the leak was stopped.…

An explosion at a hydrogen recovery plant resulted in the injury of 10 people.
The incident affected the raw material buffer tank (design pressure 0. 38 MPa) of a diesel hydrogenation unit in a refinery. This buffer tank is located between the hydrogenation reactor and the raw…

An explosion and fire broke out at a heavy oil direct desulfurization unit at a refinery. The location of the explosion was approximately at 20 meters height. The fire burned within a radius of…

The incident occurred in a hydrocracker unit of the refinery. A control valve on the liquid line between the high- and the low-pressure separators was erroneously opened and the liquid allowed to…
The explosion occurred in a benzene production unit (Litol process), which was being restarted following a scheduled shutdown for maintenance. About 30 kilograms of hydrogen gas were relesed into a…
At the time of the incident, the desulphurisation unit was shut down for scheduled cleaning of a cooling tower with reintroduction of a gas mixture into the system at a high hydrogen content. The…
SUMMARY The explosion occurred in a catalyst regenerator of the catalytic cracking unit in a fluidized bed during a technical shutdown. A few seconds later, a second explosion is perceived, it is the…
An explosion at a coal plant occurred as a steam methane reformer was being reactivated.
The naphtha and hydrogen gas leaked out from the gasoline reformer at the Southwest Petroleum as the relief-valve was operated after its repair. Although the source (Asian database ADRC) does not…
In a residual-oil hydrotreatment unit (also called residual oil hydrogenation) plant, a hydrogenation unit caught fire with a huge bang, followed by a fireball in the form of a mushroom cloud. Black…
An explosion or fire occurred in a hydro-treatment unit which was processing Fluid Catalytic Cracking feedstock. It was caused by a failure in a pipe downstream from a separator, resulting in the…
An explosion occurred in a hydrocracking reactor fitted with TOC which is a automatic cut-off system for raw oil and hydrogen supply. On the day of the incident, the operation was stopped with TOC…
A reactor of a wide-range hydrocracking unit being operated by computer at 2500 psi (170 bar) failed explosively due to localised heating. Resulting explosion caused injuries and widespread damage to…

The explosion occurred at a sand oil an explosion and affected the hydrogen compressor and its building, serving the hydrocracker unit. (1) More than two months before the incident, a large…

A gas mixture (25% nitrogen, 73% of hydrogen, 2% methane) leaked, due to the ejection of the check valve from its connection with the inlet pipe. A large amount of the gas mixed with air and ignited,…
An explosion at a refinery happened inside a hydrogen heater when a hydrogen line ruptured.