The event occurred at a hydrogen tank (another source reports a 'conduit in an enclosed space') of a hydrogen generation unit of a refinery. The explosion caused a flare and a displacement of air…

An internal explosion occurred in a cone-roof gas oil tank. The explosion completely ruptured the weak roof-to-shell weld seam and projected the roof into the diked area beside the tank. The…

The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90° elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre…
The event started at the effluent pipe of one of the hydro-cracking reactors, which broke and released a mixture of hydrogen, light gases (methane, butane), light gasoline; heavy gasoline; gas oil.…
A section of effluent piping ruptured on the hydrocracker reactor of a refinery. A mixture of light gases (methane, butane), light and heavy gasoline, gas oil and hydrogen was released from the pipe…

The incident occurred at a heat exchanger involving gas-product mixture. The source does not specify the process, with as main component a furnace, probably a hydrodesulphurisation reactor. Due to…

The incident occurred at the hydrofining unit, refining a mixture of petroleum and diesel into Euro 3 and Euro 4 diesel. A pump feeding the reactor with the process mixture failed. Following the…

An explosion occurred in hydrogen compressor, followed by a fire, due to rupture of 4 inch suction pipe to the compressor. "there was a substantial release of hydrogen, which exploded and continued…
The release and fire occurred during what appeared to be a normal operation in a reactor section of a Residue Hydrotreater Unit, when an eight-inch pipe connected to a heat exchanger failed at the…
Several explosions occurred in one of the catalytic reforming units of the refinery, followed by a fire in the same unit. The fire derived from the explosions lasted for almost one day. The…

A series of explosions occurred in thee desulphurisation and catalytic reforming unit of the refinery, followed by fires in the same unit. The establishment is classified as Seveso Upper Tier…

Leaking hydrogen ignited a fire that burned several hours at an oil refinery.
This incident occurred at an aromatics manufacturing plant. A staff member patrolling the plant heard a strange noise and rushed to the site, where he discovered a hole in a pipe, from which hydrogen…
The explosion and fire happened in a diesel hydro-treatment unit used to desulphurise raw diesel be means of hydrogen. The facility was expected to begin full commercial operations later in 2020.
The incident occurred at the recycle hydrogen compressor of a hydro-desulphurisation unit. The compressor was equipped with a suction rectifier. The drainpipe of this rectifier had been corroded…
A fire occurred on a flange of a hydro-desulphurisation unit during start-up operations. A failure of this flange caused of the leak.
A fire occurred on a valve of a hydro-desulphurisation unit in a refinery. The failed gland was modified and fire extinguishers by steams were installed permanently .

The incident occurred in the fired heater of a hydrocracking unit. Due to overheating, about 250,000 pounds of hydrogen and naphtha mixture were accidentally released into the firebox of the fired…

This incident occurred at the fired heater of a non-further specified reactor of a refinery (probably a hydro-desulphurisation unit). A tube of the fired box failed releasing a mixture of hydrogen…

The incident started at the unit removing CO2 from the process gas stream of a hydrocracking facility. (Catalysed Removal of Carbon Dioxide = Catacarb). Localized corrosion caused a pipe to fail and…