HIAD Facility - Application Type: Petrochemical Industry


The vessel affected by the incident was a gas storage used for the hydro-desulphurisation process. The desulphurisation gas had high hydrogen content. The vessels had cracks in the upper transverse…
The bonnet of a 2-inch valve on a hydrogen quench line of a lube oil hydrotreater began to leak. 12 minutes later ignition occurred with fire engulfing the upper portion of the unit. The operative…
The event affected the hydrocracker unit. A sudden release into a cracker compressor flare header destroyed a safety relief valve and damaged a sight glass on a liquid collection pot. As a…
A leak occurred on a line connecting the hot separator to the cold separator of a refinery diesel desulphurization. The alert was given by the activation of the fixed H2S detector. The 30 bar…
A hydrogen leak occurred on a makeup gas line of a gas oil hydrotreater unit of a refinery. The release location was a 1-inch gate valve, which later was found 10% open and with no bull plug. The…
A sudden failure occured on a hydrogen line of a refinery desulphurisation unit. The equipment was located between a hydrogen compressor and its overpressure protection valve. It was equipped with an…
Compressed hydrogen was released from a storage system due to the rupture of a Bourdon-type pressure gauge. [Zalosh and Short, 1978]
A hydrogen feed line ruptured without igniting at an oil refinery.
a hydrogen recycle compressor shut down unexpectedly, resulting in flaring activity with visible smoke.
A small hydrogen leak occurred during routine maintenance on an oil refinery unit not in operation.
Leaking hydrogen ignited at a plant that processes bitumen from oil sands.
Following the breakdown of a piston rod, a mixture of hydrogen and light hydrocarbons was released from the fresh hydrogen compressor of an oil refinery. The rod broke down because of stress…
During the start-up operation (phase) of a cryogenic unit, a separator exploded, releasing ethane, ethylene, methane and hydrogen. The bursting of a tank was caused by a 1600 mm long incipient crack…
The accident occurred on one of the heat exchangers of the hydro-desulphurisation unit. The role of the exchanger , located between the charge pumps and the furnace, was to heat the charge using the…
A leak of a flammable mixture of hydrocarbons and hydrogen from a ruptured pipeline caused an explosion and fire, killing one person and injuring forty six. Investigations into the incident found…
The leak occurred on the inlet pipe (P=21 bar, T=320°C) of the diesel desulphurization reactor of a refinery. Hydrogen and diesel fuel were released in the gas phase. The hydrocarbons contaminates…
A release occurred following the rupture of a pipe of 250 mm in diameter. 350 kg were released to the atmosphere in 11 minutes, consisting in 80% of hydrogen, 5% of hydrogen sulphide (H2S) and 4% of…
During a stop of the operations for maintenance and repairs, a worker was cold-cutting a hydrogen piping supposedly purged before. This caused a release of hydrogen. Realising this, the worker…
The operator detected a leak of aerosol hydrocarbons (diesel, hydrogen and hydrogen sulphide) in the diesel desulphurisation unit, causing a release of hydrogen and hydrogen sulphide at the top of…
The incident occurred in the hydrogenation reactor and products cooling unit. The reactor operated under vacuum conditions and the cooling medium was water. Toxic, flammable and explosive substances…