Skip to main content

Explosion at a hydrocracking reactor of a refinery (614)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion at a hydrocracking reactor of a refinery

An explosion occurred in a hydrocracking reactor fitted with TOC which is a automatic cut-off system for raw oil and hydrogen supply. On the day of the incident, the operation was stopped with TOC being triggered, but the cause was not identified. Hydrogen circulation was restarted, and some 5 hours later, the loud explosion took place around a low pressure separator, rupturing the reactor and throwing debris in all directions. The contents were released to form a vapour cloud which ignited followed by a fire ball.
Event Date
January 1, 1987
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Facility Information
Application Type
Application
Hydrocracking process
Specific Application Supply Chain Stage
Components Involved
oil and raw supply, low pressure separator, reactor
Location Type
Location description
A TOC is an automatic cut-off system for the supply of raw oil (feedstock) and hydrogen. It is designed to stop the flow of highly flammable materials into the hydrocracking reactor in an emergency, such as a fire or explosion, to prevent the incident from escalating.
Operational Condition
Pre-event Summary

The pre-event related to the hydrogen-event was an automatic stop of the unit, before the hydrogen was recirculated.

Consequences
Number of Injured Persons
1
Number of Fatalities
0
Event Nature
Release Type
Release Substance
unknown
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Orignal source lost. RISCAD is closed.