Near miss on a flange of a heat exchanger in a refinery
An operator noted a loose tube sheet flange stud on a high temperature, high pressure heat exchanger in an hydrodealkylation unit. The stud was found to be cracked through. Analysis proved to be made of standard steel instead of the alloy type specified. Some of the other studs had started to crack. The studs had been replaced on the previous shutdown when the heat exchanger was opened up to clean the tube bundle.
Event Date
January 1, 1976
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
Maintenance inadequate and incorrect material of construction crack