Skip to main content

HIAD Consequences - Currency: USD - US Dollar


A LH2 trailer was delivering at a customer’s site. Just after having terminated the transfer to the stationary tank approximately 13000 gallons (3500 kg) of liquid hydrogen, the pressure relief valve…

A small fire developed at the connection hose between the LH2 delivery trailer and the customer stationary tank. The driver intervened to isolate the hose first on the delivery side, and then at…

A liquid hydrogen tanker was returning empty to the home terminal after delivery to a customer. At a stop, the drivers executed a visual inspection of the vehicle and noticed an accumulation of…

The incident occurred at the hydrocracker unit of a refinery. A mixture of hydrogen and hydrocarbon gas was accidentally released. The flammable gas formed a vapour cloud that ignited, resulting…

The incident occurred while transferring gaseous hydrogen from a tube trailer to a customer stationary supply system. The transfer hose ruptured and released hydrogen which ignited explosively.…

The incident occurred at a reactor vessel of a naphtha hydrotreater unit. The vessel operated at around 25 bar and 140 C. A 1. 5-meter crack opened up in the reactor vessel close to welded vessel…

An explosion and fire occurred at a reciprocating recycle hydrogen compressor during commissioning of a new Diesel hydrotreatement Unit. It happened during the reactor pre-sulphidisation step, when…
The incident occurred at the hydrocracker unit, which was being shut down for maintenance and the reactor was in a hydrogen purge cycle. A hydrogen gas line failed at a weld. The line was at 3000 psi…
A hot oil line (8-inch) in the hydro-desulphurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343°C sprayed across the roadway into the hydrogen units where ignition occurred…

While travelling to deliver liquid hydrogen to a customer, a tanker experienced an increase of the internal pressure of the cargo tank. The drivers pulled off the road and at that moment the…

A CGH2 trailer-tractor arrived at a customer’s site for delivery. When stopping at gate and coming out of the cab, the driver noticed a noise coming from the rear of the trailer. The driver opened…

This incident occurred when delivering hydrogen to a stationary hydrogen tank at a customer site. After transferring from the first 2 tubes, the driver began to transfer from the 3rd tube. At this…

A liquid hydrogen tanker was returning to base terminal after having delivered at a space centre, when the driver noticed excessive venting of hydrogen gas vapour from the rear . The driver pulled…

An empty liquid hydrogen tanker was returning to home terminal after having delivered at a space centre. A motorist passed by and pointed to the rear of the tanker. The driver stopped the vehicle…

An empty liquid hydrogen tanker was returning to the base terminal after having delivered at a customer (approximately 4 hour and 200 miles). The drivers noticed vapour coming from the vent stack…

A liquid-hydrogen tanker was on a journey to deliver to a customer. While performing a routine tire check, the driver discovered a leak in the plumbing. The driver brought the vehicle away from…

A liquid hydrogen tanker-tractor was travelling on a highway, when the drivers noticed vapour coming from the tank. They pulled the vehicle safely off the road and discovered that the vapour was…

The driver of a liquid hydrogen tanker noticed a small vapour plume in his mirror while driving. The driver stopped and found the packing nut had loosened on the vapour recovery valve causing the…

The drivers of a CGH2 tube trailer-tractor was travelling to a delivery. they stopped to perform a visual walk-around inspection of the vehicle and discovered an audible leak coming from the neck…

A liquid hydrogen tanker was travelling on a highway, when it overturned. The product remained secure within the trailer and there was release to atmosphere during the accident. During the clean…