Skip to main content

Leak from a valve of a LH2 tanker (75)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Leak from a valve of a LH2 tanker

The driver of a liquid hydrogen tanker noticed a small vapour plume in his mirror while driving. The driver stopped and found the packing nut had loosened on the vapour recovery valve causing the valve to crack open. The driver closed the valve and tightened the packing nut. The vapour stopped and the driver continued on to complete trip without further incident.

Event Date
November 11, 1991
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

The INITIATING cause of the hydrogen release was the loosening of valve packing nut. The ROOT CAUSE was identified by the PHMSA report with over pressurisation. However, the loosening of the packing nut could more plausibly be attributed to road vibrations.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

packing nut, valve

Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

Unknown if the tanker was containing liquid hydrogen or only cold hydrogen vapour.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

3

Property Loss (offsite)

0

Post-event Summary

PHMSA reports a minimal loss of hydrogen of 60 GCF, which probably correspond to 0. 2 kg

Event Nature
Emergency Action

The driver closed the valve and tightened the packing nut.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Event incident ID I-1991110674 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996), https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages (accessed September 2024)