Skip to main content

HIAD Consequences - Currency: USD - US Dollar


[Note of HIAD event validator: the description of this incident presents aspects which hinder the full understanding of the event sequence: for example, the PHMSA report uses the term ‘purge’ to…

A CGH2 tube trailer was parked at a gas shipping site and was transferring gaseous hydrogen to a stationary storage system. The transfer hose failed releasing hydrogen, which ignited. The…

During transfer from a tank trailer to a stationary storage tank, a leak developed resulting in an unignited release. [Zalosh and Short, 1978]

A LH2 road transporter experienced a fire on a rear tire. The driver tried unsuccessfully to extinguish the fire out with the on-board fire extinguisher, then he called the 911 and disconnected the…
A CGH2 tube trailer had been filled at the production facility and was parked awaiting pickup by the company. A rupture disc failed on one of the cylinders resulting in the release to the atmosphere…
A liquid hydrogen tanker was travelling on a highway, when the driver noticed vapour exiting the rear tanker cabinet. The driver stopped the vehicle in a safe location and discovered that the vapour…
The incident happened during a liquid hydrogen delivery at a customer site. When the drivers were pressuring up the tanker for product transfer, the safety relief system rupture disc failed…

A faulty rupture disc failed prematurely releasing 750 cu ft of hydrogen (0. 2 kg). [Zalosh and Short, 1978]

The vacuum on a liquid hydrogen tanker was lost, resulting in a hydrogen release, both manually and through bursting of burst disc [Zalosh and Short, 1978]

A faulty burst disc on a liquid hydrogen tanker failed prematurely releasing 750 cu. ft. of of hydrogen. [Zalosh and Short, 1978]

Due to a loss of confinement of the inner shell of the liquid hydrogen tank, the vacuum of the external shell was destroyed. The reduced thermal insulation capacity of the shell caused evaporation…

The vent valve on a liquid hydrogen tanker vibrated open allowing a slight discharge hydrogen. [Zalosh and Short, 1978]

An unexplained loss of vacuum resulted in the release of all the transported hydrogen by manual venting and and opening of the relief valve. [Zalosh and Short, 1978]

A LH2 trailer was preparing to unload, when the pressure in the tank rose to about 165 psi (11. 3 bar) and caused the burst disc to rupture. The whole tank content was vented to atmosphere.

Furnace tube leak caused excessive heat on H2 tube causing rupture [Zalosh and Short, 1978]

Compressed hydrogen escaped from reactor due to faulty gasket [Zalosh and Short, 1978]

A liquid hydrogen trailer was delivering hydrogen at a customer site. The operation was occurring at the correct pressure, when one burst disc failed prematurely. No ignition occurred. The…

A liquid hydrogen trailer stopped on highway due to traffic accident ahead. A second vehicle struck the trailer in rear at a high rate of speed, causing it to crash into another vehicle ahead. The…

A vehicle transporting 54 compressed hydrogen cylinders stopped at a railroad crossing and was struck from behind by a tractor trailer that did not slow down. Due to the impact, the cylinders were…

The incident occurred at one mile from the start of the journey, which probably was a return journey to the base. The driver was making a left turn when the trailer disconnected from the tractor mid…