Skip to main content

Road collision involving hydrogen trailer (1134)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Road collision involving hydrogen trailer

A vehicle transporting 54 compressed hydrogen cylinders stopped at a railroad crossing and was struck from behind by a tractor trailer that did not slow down. Due to the impact, the cylinders were thrown from the vehicle. Three of them had the cylinder caps destroyed by hitting the road, broke the valves releasing hydrogen. The hydrogen was allowed to vent till emptying the cylinders without any intervention.

Event Date
March 15, 2005
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

INITIATING CAUSE was a traffic accident. In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).

Facility Information
Application
CGH2 cylinders truck
Specific Application Supply Chain Stage
Components Involved

valve

Storage/Process Medium
Storage/Process Quantity
38
Actual Pressure
16
Design Pressure
16
Location Type
Location description

DESCRIPTION OF THE UNIT According to PHMSA, each cylinder contained 300 gas-cubic feet of hydrogen. Three cylinders were damaged and released 900 gas-ft3. If these values are correct, it corresponds to ca. 2. 1 kg of hydrogen released. The total transported hydrogen, in 54 cylinders, was then ca. 39 kg

Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

45045

Property Loss (offsite)

0

Post-event Summary

The driver of the other truck that struck the rear of the Linde truck was killed upon impact.

Event Nature
Emergency Action

No attempt to stop the leak was made, because the safest way to deal with was to allow hydrogen to vent and empty the cylinders without

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident E-2005040157 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)