Skip to main content

Release while transferring LH2 (1128)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Release while transferring LH2

A liquid hydrogen trailer was delivering hydrogen at a customer site. The operation was occurring at the correct pressure, when one burst disc failed prematurely. No ignition occurred. The transfer system was provided of two line, each with its own burst disc. Therefore, followed the protocol, the driver activated the diverter valve, which directed the hydrogen flow to the secondary burst disc line. However, the driver was unable to fully divert the flow due to the presence of a small piece of the ruptured burst disc. He contacted the depot management for direction. The depot management contacted a third party provider, who succeeded to get the diverter to engage fully to the secondary burst disc. The trailer was taken to the third party provider for the necessary repairs, after having reduced the tank internal pressure. The source does not tell if the LH2 transfer was completed successfully.

Event Date
March 11, 2015
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

INITIAL CAUSE was the premature failure of a burst disc. It was probably due to deterioration or aging ROOT CAUSE unknown

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

burst disc

Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

0

Property Loss (offsite)

0

Event Nature
Emergency Action

Following the protocol, the driver activated the diverter valve, re-directing the hydrogen flow to the secondary burst disc line. However, the driver was unable to fully divert the flow due to the presence of a small piece of the ruptured burst disc. He contacted the depot management for direction. The depot management contacted a third party provider, who succeeded to get the diverter to engage fully to the secondary burst disc. The tanker was taken to the third party provider for the necessary repairs, after having reduced the tank internal pressure.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident I-2015040560 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)