HIAD Consequences - Currency: USD - US Dollar


A tanker was travelling on a highway, when a passing motorist notified a problem with the tanker to the drivers. They pulled the unit safely off the highway, went to rear of the tanker and opened the…
The truck was delivering hydrogen to a steel products plant. It contained approximately 8500 gallon of liquid hydrogen. The operation of transfer to the customer tank had just terminated. The fire…

A liquid hydrogen tanker was preparing to transfer hydrogen to a stationary tank belonging to a manufacturing facility. The tanker was being pressurised before transfer, when a burst disc failed…

An empty LH2 trailer was travelling back to the baser to load new LH2, when one of the truck tyre (the inner tire on the driver’s side rear axle) blew causing sparks and smoke. The driver pulled…

The chain holding compressed hydrogen cylinders on a lorry broke. Probably the cylinders fell and due to the mechanical impact they released hydrogen resulting in a small fire [Zalosh and Short,…

The incident occurred at an ammonia production plant. The plant was starting, when a section of piping between the secondary reformer and a waste heat boiler (“transition pipe”) ruptured. Process…

An explosion of a mixture of hydrogen and hydrocarbons occurred at a fired heater of an ethylene unit of a chemical plant. The bad weather caused the shut down of the boiler units. This shutdown…

An explosion of a mixture of hydrogen and hydrocarbons occurred at a fired heater of a refinery. A mixture of a hydrogen and hydrocarbon mixture was accidentally released into the firebox of a…

An isolation failure in starter coil of the high voltage generator induced an electric arc to the hydrogen supply line, with consequent fire and melting of the line. [Zalosh and Short, 1978]

The incident occurred during maintenance works at a hydro-cracking unit of a refinery (the report does not explicitly mention the unit, but it is plausible to assume that it was a hydro-cracking…

The hydrogen release of a defect valve on the hydrogen supply line ignited due to an unknown cause. The fire caused the melting of soldered joint with consequence additional release of hydrogen at 6.…
Due to the failure of a exhaust system, compressed hydrogen leaked into an area containing electrical components, with consequent fire. Leakage was allowed when exhaust system failed.

While driving on a highway, the driver of a CGH2 tube trailer was notified by another driver of the smoke coming from his trailer. The CGH2 tube trailer parked in a place considered safe,…

A release of compressed hydrogen and subsequent fire occurred during the transportation of a CGH2 trailer by means of a truck tractor. The tube trailer module contained 25 fully wrapped carbon filler…

Safety slug in the vent pipe of a hydrogen trailer failed, damaging the pipe and causing a hydrogen leak. The following fire damaged several other trailers. [Zalosh and Short, 1978]

A fire developed at a recycle gas compressor of a refinery. During recommissioning, the compressor, belonging to a hydro-treatement unit, was overpressurised. The cylinder head was blown off,…

30 pounds of gaseous hydrogen (14 kg) were accidentally released from a heat exchanger at a refinery. The location was the flange between the heat exchanger channel and shell and occurred during…

Gaseous hydrogen release in generator caused by turbine vibrations [Zalosh and Short, 1978]
The fire developed an early morning on a hydrogen bus at a refuelling station for public transport. According to the bus company release, one bus was destroyed by fire suring refilling and the…

A trailer-tractor carrying liquid hydrogen had been parked nearly 36 hours when the rupture disc blew. This resulted in a hydrogen plume which ignited. The fire continued until it ran out of fuel.…