Skip to main content

Fire on a LH2 trailer (1123)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Fire on a LH2 trailer

A trailer-tractor carrying liquid hydrogen had been parked nearly 36 hours when the rupture disc blew. This resulted in a hydrogen plume which ignited. The fire continued until it ran out of fuel. [Note of HIAD Validator: considering the little amount of LH2 declared as lost, it could be concluded that the trailer was almost empty. ]

Event Date
May 14, 2011
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

The INITIAL CAUSE was the opening of the burst disc due to internal over-pressure The ROOT CAUSE was probably no respecting the procedures. It is to be expected that after three days the heat flow through the thermal insulation of a LH2 cryogenic vessel will begin to heat the liquid, increasing evaporation and internal pressure.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

burst disc

Storage/Process Medium
Storage/Process Quantity
3486
Location Type
Operational Condition
Pre-event Summary

The trailer had been parked for 36 hours.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

0

Property Loss (offsite)

0

Post-event Summary

No injury, only a loss of hydrogen (17 kg)

Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident E-2011060224 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)