This incident occurred at a fired heater of an ethylene unit of a chemical plant. The fired heaters was shutdown. A mixture of hydrocarbons and hydrogen flew back from the unit to a tube of the…
An explosion occurred in a nitrogen wash cold box (outside the equipment) after a several day cold shutdown followed by a derime with nitrogen. It is assumed that ice may have split tubes…
A steel hydrogen pipeline failed with a circumferential rupture, at a location where a leak had been already detected and repaired. The leak was discovered during a one-call response for planned…
A collision between two vehicles occurred at the corner of two streets. One vehicle was a fuel cells and hydrogen vehicle (FCEV), the other was a conventional one. Its driver incorrectly did not…
The incident occurred in the fired heater of a hydrocracking unit. Due to overheating, about 250,000 pounds of hydrogen and naphtha mixture were accidentally released into the firebox of the fired…
This incident occurred at the fired heater of a non-further specified reactor of a refinery (probably a hydro-desulphurisation unit). A tube of the fired box failed releasing a mixture of hydrogen…
This incident occurred at a unit designed to convert heavy oil residues into refined products. It involved a fluidized bed reactor and the related hydrogen supply system serving the optimisation…
This incident occurred at a at an electronics plant. While transferring of hydrogen from a compressed hydrogen tube trailer to stationary cylinder banks, a leak developed on the transfer hose and…
A LH2 trailer was delivering at a customer location. The LH2 transfer had just been terminated and the driver was ready to depressurise the trailer to remove the hose. When he started to open the…
A compressed hydrogen tube trailer was fully loaded and parked in the sun. The heat caused a pressure build-up, so that a burst disc failed prematurely venting hydrogen, which ignited. 13,360 cu…
A compressed hydrogen tube trailer was fully loaded and parked, when a rupture disc on one of the tubes failed. The escaping hydrogen ignited. 9583 cu ft were released. [Zalosh and Short, 1978]…
The incident occurred at the site of a gas production company. During the filling of a compressed hydrogen trailer, an end plug thermal pressure relief device (TPRD) had an unplanned activation.…
We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.