Leak from a LH2 tanker
A liquid hydrogen tanker was returning to base terminal after having delivered at a space centre, when the driver noticed excessive venting of hydrogen gas vapour from the rear . The driver pulled off the road at a safe location and discovered that the vent valve had opened due to vibration. The driver closed the valve and continued safety back to the base. An inspection of the valve found a crack in the silver braze on the valve stem tube, which caused the venting. The valve was removed for repair and the tanker was returned to service.
Event Date
March 28, 1994
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences

The INITIATING CAUSE was a leak through the vent valve. The report provides two reasons for the leakage: (i) the opening of a vent valve due to vibration and (ii) a crack in the pipe. It is also unclear how a leak through a crack in a pipe could be stopped by closing a valve. Therefore, the ROOT CAUSE can be attributed to a mechanical/material failure and to design shortcoming.