Skip to main content

Leak from a LH2 tanker (378)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Leak from a LH2 tanker

An empty liquid hydrogen tanker was returning to the base terminal after having delivered at a customer (approximately 4 hour and 200 miles). The drivers noticed vapour coming from the vent stack at the rear of the tanker. They stopped the vehicle and discovered that the vent valve had vibrated open since the last safety check. They closed the valve, ensured that everything else was safe and secure, and continued to the base terminal. No defects were found after inspection at the terminal.

Event Date
November 30, 1992
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING cause was the slightly opening of a valve due to road vibration. The ROOT CAUSE was a design which did not took into account the whole range of mechanical solicitations which the pressure control system of the trailer could experiment when travelling.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

vent valve

Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

4

Property Loss (offsite)

0

Lessons Learned

This case, as several similar one, could have a lesson learnt similar to case 70

Event Nature
Emergency Action

The leaking valve was closed by the driver.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Report I-1992120298 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)