Leak from a LH2 tanker
An empty liquid hydrogen tanker was returning to home terminal after having delivered at a space centre. A motorist passed by and pointed to the rear of the tanker. The driver stopped the vehicle and noticed that a small amount of hydrogen vapour was coming out of the vent stack. The driver found that the vent valve had vibrated open and was releasing hydrogen vapour through the vent stack. The driver secured the valve and returned to the base with no further incident. No defects were found after inspection at the home terminal.
Event Date
April 14, 1993
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIAL CAUSE was the release of a small quantity of hydrogen through a partially loose vent valve. The ROOT CAUSE is not given. Similar cases have been attributed to road vibration (shortcoming In design), but it could be as well related to a non-completely tight closure of the vent valve after operation (procedure not properly followed)