A truck was traveling on a highway carrying three hydrogen pallets. When trying to pass a vehicle ahead, the driver moved too far to the right, causing the wheels to hitting a snow-covered…

The trailer overturned and due to the impact released the whole trailer content to the atmosphere. After which the truck and the trailer could be put back on wheels. (The driver could not deliver…

During the start-up of a propylene hydrogenation reactor, very high temperatures were generated in the catalyst bed. At the time, propylene and hydrogen were being fed to the reactor which contained…
A petroleum refinery experienced a catastrophic rupture of a heat exchanger in the catalytic reformer / naphtha hydrotreater unit. The heat exchanger catastrophically ruptured because of High…
Around 60 people gathered in a small theatre at a shopping centre to watch an array of scientific experiments, including a "small hydrogen explosion. " Several children suffered second degree burns…

This event summarises 3 very similar cases of leaks at dispenser hoses during refuelling, occurred at the same hydrogen refuelling station in the period January - April 2017. The leaks triggered…

A fire broke out at an oil refinery and caused a hydrogen reformer to shut down.

The incident occurred in the new Residue Upgradation Facility unit of the refinery, which converts the heaviest oils from crude oil into high-quality, cleaner fuels such as Euro 6 diesel. The unit…

A leak occurred when transferring hydrogen from a trailer to the customer storage. The driver had just completed the pre-fill procedures and was starting to apply pressure to the fill hose, when…

"A leak occurred when transferring gaseous hydrogen from a tube trailer to the well of a hydrogen underground storage test facility. The leak was located at a threaded fitting which was part…

When a CGH2 tube trailer was backing into the terminal stall and getting ready to unhook the tractor a leak was detected on one of the cylinders. It was reported immediately to owner of the…

A driver found a small audible leak coming from the rear of the trailer compartment, while conducting in-trip visual walk-around inspection at a roadside. The driver set up perimeter around…

A leak developed on a CGH2 tube trailer on the pigtail of one of the tube. The pigtail was cracked, possibly due to vibration. This trailer was tested the day before this incident and was found to…

The incident occurred at the steam methane reformer unit producing hydrogen. The event occurred just after that start-up steam was introduced into the reformer furnace inlet. At this moment a very…
A university lab was investigating the production of hydrogen and methane from biomass made of wooden chips or sawdust. The experimental furnace was a concrete cylindrical furnace of the diameter of…
There was a small leak of syngas (a mixture mainly consisting of hydrogen and carbon monoxide) resulting in a localised fire at a bolted flange joint on the outlet carbon steel pipework of the High…
The leak occurred at the ammonia reactor after a technical shutdown of 4 days. When the production was resumed and the syngas compressor restarted 14 hours later, a jet-fire occurred. The Internal…

The incident occurred at the ammonia synthesis unit of a production plant of fertilizers (Seveso III upper tier), during the operation of start-up. The unit was restarting, when a pipe carrying…

Following a trip caused by the safeguarding of an ammonia production line, the syngas released into the atmosphere and ignited.
The event occurred while re-starting the ammonia production unit after a technical stop, a synthesis gas (50% hydrogen, 17% ammonia, methane and nitrogen) leak ignited on a flange located just after…