HIAD Facility - Storage Medium: Gas


A hydrogen pipe burst at a semiconductor plant injuring 1 person

A fire broke out at a pipe of the hydrogen production unit, belonging to the steam methane reformer part of the fluidised catalytic cracking (FCC) plant. The fire occurred when personnel of a…

A hydrogen explosion ruptured and fragmented a 6-inch steam condensate pipe elbow at of a nuclear plant. The component affected was a steam piping of a heat exchanger used for removing residual heat…
The utility production facilities (electricity, water, air, and steam) at a refinery were isolated from the power grid and switched to two turbine generators in anticipation of a storm. However, at 9…

A CGH2 tube trailer was transferring hydrogen to a customer cylinder skid. The pressure relief on the customer system opened, the escaping hydrogen ignited and burned for approximately 10-15…

The vessel affected by the incident was a gas storage used for the hydro-desulphurisation process. The desulphurisation gas had high hydrogen content. The vessels had cracks in the upper transverse…
In a chemical plant , a process gas leak (4% ammonia and 88% hydrogen) occurs during a purge operation. The cloud of gas ignites and explodes. An employee is killed.
A hydrogen leak occurred at a tube bundle container at the loading and unloading bay of a PSA (Pressure Swing Adsorption) hydrogen production plant. During the hydrogen filling process, a worker in…
The bonnet of a 2-inch valve on a hydrogen quench line of a lube oil hydrotreater began to leak. 12 minutes later ignition occurred with fire engulfing the upper portion of the unit. The operative…
A hydrogen release and subsequent fire occurred at meter station of a pipeline transporting hydrogen to a refinery. Local refinery emergency response team responded and secured the area. The pipeline…
Release from a welding of a hydrogen transmission pipeline At 12:45 pm the operation control centre (OCC) recognised that a customer flow and pressure dropped significantly. At 13:28 the OCC made the…
At 17:30 on 5 may 2019, the pipeline operator was notified by a third party that there was a possible leak on its hydrogen pipeline, as identified by sound. Operator personnel arrived on the site at…
Early in the morning of (3:00 AM), the personnel on one of the companies on site reported a potential pipeline leak just south of the valve station. The potential leak was discovered due to bubbling…
An in-line inspection of the hydrogen pipeline was being conducted and prior to the last run of the in-line inspection tool (magnetic flux leakage), hydrogen gas was released and ignited from a blind…
A tractor - semitrailer with horizontally mounted cylinders filled with compressed hydrogen struck a northbound pickup truck that had veered in front of it. The tractor-semitrailer then lost control…

During a gaseous hydrogen trailer filling operation, a burst disc relieved, causing a gas release. The gas flow caused the vent pipe to separate at the flared tube fitting, resulting in a fire.…

[Note of HIAD event validator: the description of this incident presents aspects which hinder the full understanding of the event sequence: for example, the PHMSA report uses the term ‘purge’ to…

While de-plugging a cooling circuit, a blockage suddenly released, causing a heavy movement of a flexible hose connected to the system. The flexible hose hit several small pipes and one employee…
Minor leak in the break-away coupling for 35MPa dispenser of a refuelling station for buses. The leak developed in the break-away coupling during a controlled test refuel. The test was attended by…
The event affected the hydrocracker unit. A sudden release into a cracker compressor flare header destroyed a safety relief valve and damaged a sight glass on a liquid collection pot. As a…