A hydrogen compressor had been shut down for repairs and was being put back into service when the explosion occurred, causing damage . The compressor was equipped with interchangeable in take and…
During the J-2 engine testing program, the engine start tank was pressurised. The pressure raised to an excess of 1500 psi (ca. 105 bar). The venting of the tank was attempted but remained…
A steel hydrogen pipeline failed with a circumferential rupture, at a location where a leak had been already detected and repaired. The leak was discovered during a one-call response for planned…
The explosion occurred at the hydro-deoxygenation unit of a renewable fuels facility. Part of this unit is a furnace aiming at pre-heating renewable feedstock, recycled renewable diesel, and…
The incident occurred at the residual de-sulphurisation (RDS) unit of a refinery, during the initial start-up phase, consisting of the pressurisation by hydrogen of the unit reactors and the…
During startup of the hydrodesulphurisation unit, diesel and hydrogen leaked from a flange near the heat exchanger. The flammable mixture ignited spontaneously, causing a fire. Plant personnel…
The incident occurred at an ammonia production plant. The plant was starting, when a section of piping between the secondary reformer and a waste heat boiler (“transition pipe”) ruptured. Process…
The incident occurred during maintenance works at a hydro-cracking unit of a refinery (the report does not explicitly mention the unit, but it is plausible to assume that it was a hydro-cracking…
The event occurred at a liquid hydrogen spheric storage consisting of two large spheric vessels. A working team began a procedure to sample the LH2 storage vessels and the associated transfer pipe…
30 pounds of gaseous hydrogen (14 kg) were accidentally released from a heat exchanger at a refinery. The location was the flange between the heat exchanger channel and shell and occurred during…
The event occurred at a high-temperature heat of at a benzene manufacturing plant using a dealkylation reaction. High-pressure hydrogen leaked from a flange of the heat exchanger, during start-up…
The incident occurred at a university facility, in the premises of a spin-off company. A worker was checking the hydrogen pressure by opening the main valve on a hydrogen cylinder, when hydrogen…