Skip to main content

HIAD Facility - Location Type: Confined


A runaway chemical reaction happened in a reactor containing methanol and a substance to be hydrogenated. A large quantity of hydrogen was released; a balloon containing a borohydride exploded.…

The incident occurred at a storage tank of an organic chemical plant. The storage tank was containing cyclo-dodecane (C12H24, melting point: 60 °C), and a tank trucks was being filled at the…

This event occurred at the accelerator bubble chamber facility. During final stages of chmaber cooldown and its loading with LH2 (95% fill, about 95 gallons), an explosion and fire occurred…

The event occurred at one of the unit producing iron powder, consisting of a furnace with a running belt for the powder, kept under hydrogen atmosphere to reduce and purify the metal. The hydrogen…

The incident occurred at a chemical laboratory of a university. Six students were conducting experiments on producing nitrification carriers for waste leaching when an explosion followed by a fire…

An explosion and fire occurred at around at a company specialised in hydrogen storage in slid materials. The accident occurred while a press used to compact magnesium hydride and natural graphite…
The explosion occurred in a benzene production unit (Litol process), which was being restarted following a scheduled shutdown for maintenance. About 30 kilograms of hydrogen gas were relesed into a…
A violent explosion occurred at a blast furnace. The explosion occurred while the blast furnace was being cleaned at the end of casting. For this purpose, worker poured the contents of a casting…
In a chlorine electrolysis facility, a mixture of oxygen and hydrogen in one of the electrolyser cells a short-circuit ignited causing a deflagration. The cover of the cell was a thin plastic film…
An explosion occurred at a chlorine production plant during the restart of the installation. An hydraulic syphon had probably been blocked by fire extinguishing products following a previous fire on…
An explosion or fire occurred in a hydro-treatment unit which was processing Fluid Catalytic Cracking feedstock. It was caused by a failure in a pipe downstream from a separator, resulting in the…

The explosion occurred at a sand oil an explosion and affected the hydrogen compressor and its building, serving the hydrocracker unit. (1) More than two months before the incident, a large…

An explosion of unknown cause occurred at a hydrogen manufacturing plant. The explosion occurred on the second floor of the building, used by employees as a cafeteria and offices. The company where…
The explosion occurred at the hydrogen producing unit of a refinery. A solution of potassium carbonate was being drawn off from an absorption tower to a temporary storage tank for a turnaround…
An explosion took place at a research facility of a university, due to an accidental release of hydrogen. Hydrogen gas was used in research reactors to deposit amorphous silicon thin films. The…
The event occurred in the steam condensing line of the residual heat removal system the nuclear reactor. Radiolysis generated hydrogen and oxygen, which then accumulated in high concentration in the…
At a rubber factory, an explosion occurred inside a lubricant container filled with 18 tonnes of tri-(nonylphenyl) phosphate (TNPP or TNPA). This tank was typically stirred and maintained at 45°C.…
An explosion and fire occurred at a chemical plant applying silicone coatings. The blast occurred when some polymethyl hydrogen siloxane was accidentally fed into a reactor, together with the correct…

The DC power system was serving as back-up power and was based on a battery storage system. It had been taken off-line to be replaced with a more modern system. After its replacement, at the…

This incident occurred when subcontractor two workers were widening air vents on the roof of a building hosting a tank containing hydrogen chloride solution. This intervention was necessary to to…