The event occurred in an atmospheric pressure tank storing effluents. The plant was in the production phase. The head of the overfill prevention valve located at the top of the tank was thrown a…

an explosion occurred in a hydrogen storage tank at the hydrogen station of the oxygen plant of the energy centre. The 10 m3 hydrogen storage tank at the hydrogen station belonging to the oxygen…

The accident happened during testing of a hydrogen tank at a company which manufactured valves and other hydrogen-storage components. A dull bang and a huge pressure wave was felt kilometres away.…
A researcher was conducting an experiment that involved sawdust being heated at pressure using hydrogen gas in an laboratory-scale autoclave. The gas leaked from the autoclave during the experiment…

The incident occurred when cleaning the exhaust gas-processing equipment at a semiconductor factory. The inside of the water scrubber was washed with hydrofluoric acid. This is a normal operation…

The incident occurred on two hydrogen compressor units installed on the roof of a four-story building. The Great East Japan Earthquake caused the rupture of the flexible piping and the outlet piping…
The event occurred at a company producing machines for water treatment for the food industry. A pressurized tank exploded killing two workers and shaking windows and ceilings at neighbouring…
Hydrogen gas cylinders exploded at the same time in three industrial locations, when the opening valve was opened. The overpressure generated by the explosion caused the walls of the hydrogen…

An explosion occurred at a hydrogen compressor of a polysilicon plant. The head of the compressor was blown off and the released hydrogen exploded causing extensive damage to the building and to…

The event occurred at a gas cylinder manufacturing site. An explosion caused by a hydrogen cylinder injured a worker. Nothing is known on the sequence except ‘a loud bang’ reported by online news.…

The incident involved an hydrogen-on-demand unit (HOD), which was installed inside an environmental test chamber used for reliability tests. An employee was troubleshooting the chamber, assessing the…
In an electricity production plant, hydrogen leaked from a tank supplying the colant to the generator. The leaked hydrogen iognited and formed a fireball. Possible involvement of sealing oil not…
The event started when a gasket in a water pump was blown out. The water pump was situated inside a 100 m long, 10 m wide, and 7 m high building. The pump was feeding water to a vessel containing…
Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…
A tank of liquefied hydrogen felt down in a chemical plant. The tank, containing 100 m³ of liquid hydrogen, was installed on a concrete plate, which failed. The hydrogen started leaking from the…

The incident occurred during the filling of six bundles of compressed hydrogen cylinders by means of a compressor. Each bundle consisted of 16 cylinders of 40-liter each. When approaching the…

The process unit affected by the incident was a two-step production, consisting of i) hydrogenation of phenyl acetyl carbinol with benzyl amine in a isopropyl alcohol/water mixture by means of a…
The explosion occurred at a hydrogen fuel plant mainly serving hydrogen forklift fleets. The explosion damaged several nearby homes and could be felt nearly 10 miles away. Police and firefighters…
Two successive fires broke out in an interval of few minutes in four cells in the electrolysis room of a chlorine production plant. The technicians brought the fire under control using the fire…

The incident occurred in the fired heater of a hydrocracking unit. Due to overheating, about 250,000 pounds of hydrogen and naphtha mixture were accidentally released into the firebox of the fired…