Skip to main content

HIAD Facility - Application Type: Hydrogen Transport And Distribution


Pressure buildup in tank was manually vented by driver releasing 1000 cu ft [Zalosh and Short, 1978]

The tank of a liquid hydrogen tanker was manually vented prematurely on its empty return trip. 9,000 cu ft werereleased [Zalosh and Short, 1978]

While returning to the base, a liquid hydrogen tanker had to be vented twice. The cause of the overpressure was a malfunctioning scale which allowed a slight overload of hydrogen. [Zalosh and…

A hydrogen leak occurred at a plant's hydrogen fill station. After having transferred the load to the plant station storage system, a tube trailer pulled away and caught a hydrogen fill line.…

Motorway accident which involved a large quantity of vehicles and a gaseous tube trailer which transported gas hydrogen in pressure. Some cars were burning under the back part of the gaseous tube…

At an off-site LH2 fill station, a LH2 trailer hit the GH2 purge shut-off valve handle. The tubing attached to the purge valve was bent on both ends but did not leak. [Ordin, NASA (1974)]

An LH2 trailer-tractor was returning to the base after a hydrogen delivery at a customer. The trailer was almost empty. Nevertheless, the drivers noticed an increase in the trailer internal…

An LH2 trailer-tractor was returning to the base after a hydrogen delivery at a customer. The trailer was almost empty. Nevertheless, the drivers noticed an increase in the trailer internal…

An LH2 trailer had just delivered hydrogen to a customer. The vehicle exited the plant, weighted the trailer parked to get the weight receipt. While in the building, a safety device activated due…

A LH2 trailer had delivered hydrogen to a customer and on the way was heading back to base, when the tank pressure rose from 40 psi to 128 psi. The drivers stopped at a truck parking place and…

A LH2 trailer was traveling to delivery hydrogen to a customer, while the drivers noticed an increase in trailer pressure. To avoid the possibility of having the safety vent open while on the road…

A LH2 trailer/truck had delivered liquid hydrogen to a customer site and was travelling back empty to the base. The drivers noticed an increase in trailer pressure. To avoid the possibility of…

A LH2 trailer had just delivered hydrogen to a customer and was travelling on a highway returning to the base, when the driver noticed that the pressure inside the tank was increasing rapidly. The…

A full liquid hydrogen tanker was travelling from the home terminal to deliver to a customer, when the drivers noticed a pressure rise during a safety check. The drivers called in and were…

An empty liquid Hydrogen tanker was returning to the base terminal from a delivery at a space centre. At the departure, the internal vessel pressure was 8 psig. At the first safety check, the…

A liquid hydrogen tanker was loaded at the home base and dispatched to a customer (approximately 790 km). The internal vessel pressure after filling was 8 psig (1. 4 bara). During transit, the…

A liquid hydrogen tanker was travelling from the home terminal to delivery to a customer. After approximately 7 hours and 400 miles, the drivers noticed hydrogen venting from the vent stack. They…

When travelling to a customer, a liquid hydrogen tanker experienced a slight tank pressure increase due to an improper cooling down. The driver was carefully monitoring the pressure and when he…

An empty tanker was returning to the home terminal after delivery to a customer. However, the drivers had failed to properly stabilize the residue pressure in the tank before departing from the…
A liquid hydrogen tanker was travelling back to the base after having made an earlier delivery. At the end of the delivery, the pressure in the tanker had been reduced to 75 psig using the vent stack…