Skip to main content

Over pressurisation of a LH2 trailer (1116)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Over pressurisation of a LH2 trailer

A LH2 trailer had delivered hydrogen to a customer and on the way was heading back to base, when the tank pressure rose from 40 psi to 128 psi. The drivers stopped at a truck parking place and called the alarm number. The local police department gave permission to release pressure from the trailer. The fire fighters were called to stand by. The pressure was released without problems.

Event Date
August 24, 2001
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

The INITIAL CAUSE was over-pressurisation of the LH2 tank, which caused an intervention of the drivers to reduce pressure. BY using as proxy several similar events, ROOT CAUSE could be tentatively attributed to the failure to 'stabilise' the pressure of the tanker after delivery and before leaving customer's site. This is a procedure aiming at avoiding over-pressurisation by cold gaseous hydrogen during the return travel.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

Vent

Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

The driver had terminated the delivery of LH2 to a customer's site. It can be assumed that the trailer was (almost) empty.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

0

Property Loss (offsite)

0

Post-event Summary

A negligible amount of hydrogen was released.

Event Nature
Emergency Action

The emergency was quickly ended by the intervention of the drivers, who performed a manual pressure release operation.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident I-2001100429 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)