Over pressurisation of a LH2 trailer
A LH2 trailer had delivered hydrogen to a customer and on the way was heading back to base, when the tank pressure rose from 40 psi to 128 psi. The drivers stopped at a truck parking place and called the alarm number. The local police department gave permission to release pressure from the trailer. The fire fighters were called to stand by. The pressure was released without problems.
Event Date
August 24, 2001
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIAL CAUSE was over-pressurisation of the LH2 tank, which caused an intervention of the drivers to reduce pressure. BY using as proxy several similar events, ROOT CAUSE could be tentatively attributed to the failure to 'stabilise' the pressure of the tanker after delivery and before leaving customer's site. This is a procedure aiming at avoiding over-pressurisation by cold gaseous hydrogen during the return travel.