A leak occurs at a flange on a hydrogen gas transport. The load consisted of 9 cylinders of 80 m³ each. The producer of these cylinders decides to let it leak. No consequences to report.
A LH2 road transporter experienced a fire on a rear tire. The driver tried unsuccessfully to extinguish the fire out with the on-board fire extinguisher, then he called the 911 and disconnected the…
A truck loaded with hydrogen gas cylinders bundles (3 bundles of 30 cylinders, 1 bundle of 12 cylinders) was traveling on a seaside road. The nylon rope holding the bundles broke due to excessive…
A pressure relief device (frangible burst disc) on one of a 26 tubes on a tube trailers failed prematurely and released hydrogen while filling a hydrogen storage tank at a government facility. The…
A leak of 700 l of gaseous hydrogen was detected around on a connection of a rack of cylinders on a trailer truck, in aircraft plant (classified Seveso, lower tier).
A CGH2 tube trailer had been filled at the production facility and was parked awaiting pickup by the company. A rupture disc failed on one of the cylinders resulting in the release to the atmosphere…

A release of hydrogen occurred on a trailer during filling a stationary hydrogen storage tank. A pressure relief device (burst disk) on one of the tube failed prematurely and released hydrogen.…

A truck-trailer carrying compressed hydrogen cylinders stopped on an highway and reported a hydrogen leaking from the cylinders. The highway was immediately closed in both directions. When the fire…
During maintenance work on a gas pipeline carrying hydrogen , a worker hears a leak at about at a bridge. The operator measures an concentration of 3% of the low flammability limit at few centimetres…
The release occurred in the hydrogen storage system of a refuelling station. In the night a leakage occurred at one of the 120 high pressure bottles (800 bar). The leakage occurred at a screwed…
A hydrogen leak took place on a trailer carrying compressed hydrogen, located inside the fenced perimeter of a hydrogen station. According to the company managing the hydrogen delivery and refuelling…
A liquid hydrogen tanker was travelling on a highway, when the driver noticed vapour exiting the rear tanker cabinet. The driver stopped the vehicle in a safe location and discovered that the vapour…
A truck carrying 6,000 gallons of liquid hydrogen (1,600 kg) experienced an accidental loss of confinement while travelling. The truck driver noticed a white vapour cloud coming from the rear of his…
The incident happened during a liquid hydrogen delivery at a customer site. When the drivers were pressuring up the tanker for product transfer, the safety relief system rupture disc failed…

A faulty rupture disc failed prematurely releasing 750 cu ft of hydrogen (0. 2 kg). [Zalosh and Short, 1978]

The vacuum on a liquid hydrogen tanker was lost, resulting in a hydrogen release, both manually and through bursting of burst disc [Zalosh and Short, 1978]

A faulty burst disc on a liquid hydrogen tanker failed prematurely releasing 750 cu. ft. of of hydrogen. [Zalosh and Short, 1978]

Due to a loss of confinement of the inner shell of the liquid hydrogen tank, the vacuum of the external shell was destroyed. The reduced thermal insulation capacity of the shell caused evaporation…

The vent valve on a liquid hydrogen tanker vibrated open allowing a slight discharge hydrogen. [Zalosh and Short, 1978]

An unexplained loss of vacuum resulted in the release of all the transported hydrogen by manual venting and and opening of the relief valve. [Zalosh and Short, 1978]