A liquid hydrogen leak occurred at the aerospace company (high Tier Seveso). The facility is specialised in production and handling of cryogenic propellants for engines of space vehicles. A 53 m³…

A liquid hydrogen tanker was traveling west bound on a highway, when adverse weather conditions (snow and wind) caused a brief "whiteout". To avoid a group of vehicles stopped in front…

A liquid hydrogen tanker was travelling on a highway, when it overturned. The product remained secure within the trailer and there was release to atmosphere during the accident. During the clean…

A LH2 hydrogen went off road and overturned. There was no spillage. All regulatory agencies were notified and the road was closed for an extended period of time.

A liquid hydrogen tanker (with a water capacity of 2000 l) was passing a highway interchange, when the safety valve of the tank activated, releasing hydrogen gas. The drivers stopped first on the…

A liquid hydrogen tank tanker detached from the tractor due to equipment failure. The liquid hydrogen was tansferred to another tanker. During this operation a release of 58,000 cu ft occurred.…

A liquid hydrogen trailer-tractor was traveling north on a highway, when the traffic started backing up. The driver put on flashers to warn other motorists to slow down. Nevertheless, a second…
The whole content of the rail tanker, that is 42,000 l (about 3000 kg) of liquid hydrogen, was entirely lost over a period of seven hours via the venting line of a tank. The accident occurred at a…
The tanker truck was carrying nearly 13,000 gallons of liquid hydrogen (3480 kg). While turning around in the parking place of a local grocery store, the driver hit the base of a light pole. The vent…
The leak occurred on a 44 m³ vehicle of liquid hydrogen during a delivery to the unloading station of a steel plant. The truck drivers had connected the tank container to the fixed storage managed by…

According to local news, a "hydrogen tanker truck hauling was on fire" at a travel centre on a highway. The videos show, however, simply a flame from what probably is the pressure relief…

While on a highway, the driver of a liquid hydrogen tanker was notified that vapour was coming out of the back of the trailer. The driver pulled into a safe haven to investigate. After opening the…

During the transit of 10 000 gallons (ca. 39000 l) LH2 transport vessel, the venting rate became extremely high . The annular vacuum appeared to be lost showing large patches of condensed water at…

Excessive delay in trip resulted in over-pressure on the liquid hydrogen tank, requiring manual venting. This resulted in releasing of 2750 cu ft of hydrogen [Zalosh and Short, 1978]

The drivers failed to lower the internal pressure of a liquid hydrogen tanker before leaving plant. Therefore they had to stop en route and vent 4000 scf of hydrogen. [Zalosh and Short, 1978]

A liquid hydrogen tanker was returning empty to the base, when a pressure build-up forced the drivers to perform a manual venting. [Zalosh and Short, 1978]

The drivers failed to stabilise the tank pressure after having delivered the liquid hydrogen. Therefore they had to stop and perform a manual vent on journey back to the base. [Zalosh and Short,…

Before loading it with liquid hydrogen, the cyrogenic tank had been purged with nitrogen for maintenance work. After the loading, the drivers failed to stabilise the internal pressure of the tank,…

The pressure building valve opened due to vibration from the road, causing the build-up of the internal pressure. The drivers performed a hydrogen venting and re-sealed the valve. [Zalosh and…

A pressure build-up in the tank of a liquid hyrogen tanker caused the drivers to vent 6000 cu ft of hydrogen to reduce the pressure. [Zalosh and Short, 1978]