Over pressurisation of a LH2 trailer (1115)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Over pressurisation of a LH2 trailer

An LH2 trailer had just delivered hydrogen to a customer. The vehicle exited the plant, weighted the trailer parked to get the weight receipt. While in the building, a safety device activated due to excessive internal vessel pressure. The vented hydrogen vapour ignited (possibly by static electricity) resulting in a vent stack fire. Plant emergency responders, carrier safety departments, and shipper safety department were contacted. The incident was terminated successful, but the source does not explain how. Very probably, they left the fire extinguishing by itself. The hydrogen left in the tank after delivery was not in a liquid state, it was vapour only. The investigation revealed that the trailer had lost the vacuum guaranteeing thermal insulation from external heat to the LH2 tank, resulting in an increase of the vapour pressure. The safety device functioned properly and no significant quantity of product was dispersed. This trailer was safely removed from the site and taken to a qualified repair facility for further evaluation and repairs.

Event Date
July 11, 2001
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIAL CAUSE was over-pressurisation of the LH2 tank, which triggered a hydrogen venting. The ROOT or INTERMEDIATE CAUSE was a loss of the thermal insulation capacity of the tank, due to deterioration of the vacuum between the external and internal shells of the LH2 tank.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

vacuum thermal insulation

Storage/Process Medium
Storage/Process Quantity
3083
Location Type
Operational Condition
Pre-event Summary

The trailer was empty, having just delivered hydrogen to a customer site. Only gaseous hydrogen, no LH2 was left.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

0

Property Loss (offsite)

0

Post-event Summary

A negligible amount of hydrogen was released.

Event Nature
Emergency Action

The fire was probably left to extinguish itself, due to the limited amount of hydrogen left in the tank.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident I-2001080130 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)