Over pressurisation of a LH2 trailer
An LH2 trailer-tractor was returning to the base after a hydrogen delivery at a customer. The trailer was almost empty. Nevertheless, the drivers noticed an increase in the trailer internal pressure. They notified the company support team and pulled into a truck parking place, to avoid the risk of having the safety vent open while traveling. They then performed a controlled, manual venting of the trailer, going from 58 psig (4. 0 barg) to 34 psig (2. 3 barg). They then returned to the base without further incident.
Event Date
July 31, 2000
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIAL CAUSE was over-pressurisation of the LH2 tank, which caused an intervention of the drivers to reduce pressure. BY using as proxy several similar events, ROOT CAUSE could be tentatively attributed to the failure to 'stabilise' the pressure of the tanker after delivery and before leaving customer's site. This is a procedure aiming at avoiding over-pressurisation by cold gaseous hydrogen during the return travel.