Over pressurisation of a LH2 trailer
A LH2 trailer/truck had delivered liquid hydrogen to a customer site and was travelling back empty to the base. The drivers noticed an increase in trailer pressure. To avoid the possibility of having the safety vent open while traveling on the road, they moved to an isolated area, parked and performed a controlled, manual venting of the trailer. The pressure was stabilised and they returned o the base without further incident. The trailer was found to have a deteriorated vacuum, and repaired.
Event Date
July 8, 2003
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIAL CAUSE was over-pressurisation of the LH2 tank, which triggered a hydrogen venting. The ROOT or INTERMEDIATE CAUSE was a loss of the thermal insulation capacity of the tank, due to deterioration of the vacuum between the external and internal shells of the LH2 tank.