Skip to main content

HIAD Events

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.



This incident happened during a test of a hydrogen engine prototype vehicle, equipped with on-board liquefied hydrogen storage. The hydrogen gas leaked from a hose joint of a flexible pipe in the…

[Note of HIAD Validator: this event description is unsatisfactory. Details on the prototype and the incident evolution are missing]. The incident affected a prototype light hydrogen vehicle in a…
A weld on a 1 inch diameter instrument tapping from a Octafiner reactor overhead line fractured, resulting in a small but intense fire, lasting about 50 minutes until the unit was nitrogen purged.…

This event occurred when dismantling the cryostat. While a hot air dryer was being used to free a coupling in a hydrogen cryostat, a flash fire occurred. [Ordin, NASA (1974)]

During a cryo-irradiation testing, a Dewar failed or leaked hydrogen into the atmosphere, causing a fire. The Dewar's were nitrogen-walled LH2 vessels to contain metal samples for testing. In…

The event occurred when attempting to replace a rupture disk in a LH2 vessel. Hydrogen gas was released and ignited. In fighting the fire, liquid nitrogen was sprayed onto a second LH2 vessel…

A trailer-tractor carrying liquid hydrogen had been parked nearly 36 hours when the rupture disc blew. This resulted in a hydrogen plume which ignited. The fire continued until it ran out of fuel.…

A LH2 trailer was delivering at a customer’s site. Just after having terminated the transfer to the stationary tank approximately 13000 gallons (3500 kg) of liquid hydrogen, the pressure relief valve…
A fire developed on a mathanation reactor. The methanation reactor vessel was found to be deformed and had a 3-4 inch rupture at a position corresponding to the top of the catalyst bed. It is thougth…

A fire in a first stage 'pygas' (pyrolysis of gasoline) hydrogenation of a naphtha cracker was caused by escape of a mixture of gasoline, hydrogen and nickel catalyst through a crack in…

A hydrogen leak occurred on a sintering furnace in a manufactory of uranium pellets. The event happened during the restart phase after a period of maintenance. The hydrogen ignited at the location of…
A truck-trailer transporting 4,000 pounds of compressed hydrogen burned to ground, including the driver cabin. The driver was able to get out before it got fully engulfed. 3- to 4-feet of flames were…
The fire broke out under the cabin of a heavy-duty vehicle transporting industrial gas cylinders (hydrogen, acetylene, helium) close to a paint company. Firefighters shelter the employees of this…

A truck carrying hydrogen cylinders was destroyed by fire after a crash against a tree. The truck driver lost control of its vehicle when a tyre burst and took fire. The fire engulphed the whole…

A truck carrying cylinders was travelling on a highway when its front tyre burst. It rolled over in a farm and the gas started leaking from the cylinders. The driver called the emergency service.…

A trailer-truck transporting hydrogen gas cylinders was involved in a collision on a highway, experienced a partial roll-over and cough fire. The online news do not report the origin of the fire.…

A truck driver carrying compressed gas cylinders loaded on pallets stopped on the emergency stop lane of a highway after a tyre burst. The gases transported were: 120 m³ of oxygen, 24 acetylene…

A trailer-tractor carrying a liquid hydrogen took fire on a highway. The fire was due to a malfunction of the diesel engine fuel injection system. The fire engulfed the whole cabin of the tractor.…

At a chemical processing plant, a release of pressurised hydrogen gas resulted in an explosion and fire injuring lightly three workers and causing damage to plant. The incident occurred during the…

A fire broke out on the insulating plastic elements of an alkaline electrolyser in a unit of a chemical plant. The shift saw the smoke from the control room. The first action was to drain the potash…
In a chemical plant, a fire broke out on a hydrogen column of an ammonia manufacturing unit. The internal security service extinguishes the fire with powder and nitrogen injection. The unit was…

Break of pipeline in oil cracker, resulting in a continuous release in partially confined atmosphere.

The boat was performing a drive test when one of the 280 lead gel batteries exploded and took fire. The local fire brigade was able to extinguish the fire but the above deck section of the boat was…
A compressed hydrogen trailer released accidentally hydrogen which ignited producing a hissing 60 jet flame. It triggered the evacuation of a one-mile stretch. It was estimated that the tanker burned…
A hydrogen leak occurred on a 50 mm pipe feeding a reactor. The leak ignited spontaneously when mixed with air. Thanks to the closing of the input and output valves, the quantity released could be…
The incident occurred in the turbine-generator hall of a nuclear power plant. Hydrogen leaked from the alternator and ignited. The hydrogen line was purged to stop the leak. The plant employees were…
A major leak occurred at the outlet of the diesel hydrodesulphurisation furnace in a refinery. The furnace was just restarting. The released gaseous product ignited, and the alarms of the temperature…
In a petrochemical plant, a fire occurred on the methanation unit (95% H2 + 5% CO -> CH4 + H2 + H2O) of a steam cracker. A seal break on a flange of the circuit caused of the accident. No…

A tube ruptured in the charge heater ('fired heater') of a desulphurisation reactor due to a blockage caused by accelerated coking. Flames spread over an area of some 100 feet outward…

A truckload of hydrogen cylinders caught fire at plant producing artificial sweetener.