Skip to main content

HIAD Events

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.



A leak occurred while loading a trailer carrying hydrogen gas cylinders. The trailer was loaded with 4 bundles of 60 cylinders at 200 bar which were beeing refilled. The leak was heard, and an…
A hydrogen fire occurred in a nuclear power plant outside the controlled area. The leaking point was on a pipe system of the distribution circuit of the gas network (6 bar nominal working pressure).…
The incident occurred outside a fuel cells manufacturing facility. While preparing for transfer of liquid hydrogen from tanker truck to a stationary storage tank, a release of hydrogen occurred,…
A lorry loaded with gaseous hydrogen cylinders caught fire and shut a motorway. No one has been injured.
The incident occurred at the hydrocracker unit, which was being shut down for maintenance and the reactor was in a hydrogen purge cycle. A hydrogen gas line failed at a weld. The line was at 3000 psi…
The fire occurred after a hydrogen released from a venting valve opened for inspection. The hydrogen was at 300 bar and 300C centigrade and between 200 and 300 bar. The hydrogen ignited probably…

The incident occurred at a hydrogenation reactor producing alcohols. At the time of the fault, the plant was in normal operation. A sudden leak of hydrogen occurred on the flange of the upper…

A hydrogen jet fire occurred on a 25m3 tank while transferring a catalyst to a buffer tank. The constabulary created an area of safety around the plant while the staff extinguishes the fire by…
The explosion occurred in a plant for the production of butter. It was due to the rupture of a hydrogen tank, during a sterilisation process at high temperature (so-called UHT treatment). Two…
A hydrogen leak occurred on the hydrogen line of a hydro-desulphurisation unit, followed by ignition . The failure was located on a supply manifold of the unit at a support beam. The unit was shut…
Hydrogen leaked from an analyser of a unit for the production of sodium chlorate. Thehydrogen ignited. On-site staff isolate the leak very quickly, so that the amount of hydrogen released was…
A hydrogen jet fire from a pipe was detected by a night operator making rounds in a solvent production unit. The unit's emergency response team managed the fire in minutes. Operators stopped the flow…
Three workers were working in the sulphur recovery unit (SRU), trying to restore the hydrogen flow. The workers were trying to isolate the cause of a flow problem: hydrogen was entering the…
A fire was caused by a hydrogen leak and led to the formation of a fireball at the end of a hose at the conditioning station. It occurred while transferring hydrogen from a stationary storage to he…
The regular maintenance of the hydrogen production equipment had been completed and the plant was about to start up. At this point, fluid mainly composed of hydrogen was sent via a pipe to the…
The fire occurred around 13:20 on three cells of the chlorine manufacturing unit. A leak of hydrogen in the electrolysis room was at the origin of the fire; the ignition of the H2 cloud caused a…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line affected…
A hot oil line (8-inch) in the hydro-desulphurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343°C sprayed across the roadway into the hydrogen units where ignition occurred…

A hydrogen fire broke out at the aft end of the orbiter connected to the LH2 onboard tank of a space shuttle. This happened during the abortion of the launch, occurred due to another cause, the…

On February 3, 1994, a control room operator at Surry Power Station, Unit 1, observed pressure spikes on the pressurizer level instruments. At the same time, a loud rumbling sound was heard in the…

NOTE: one of the source of this event attribute the explosion to the recombination of oxygen and hydrogen formed by thermolysis. However, the classic reaction products in the case of molten metal…

[NOTE of HIAD Validator: the attribution to hydrogen formation as cause of the explosion is 'probable 'but not fully demonstrated]. Two explosions in two different sprinkler systems occurred, wit the…

A truck transporting hydrogen and oxygen cylinders collided with a passenger vehicle at an intersection and overturned, causing all cylinders containers to fall onto the road. Gas leaked from four…

After the filled hydrogen gas cylinders were unloaded onto the quay, the weather worsened and high waves caused the containers to break apart, and the cylinders were lost to the sea.

The release occurred on a pipeline inside a steam cracking unit located between two hydrogenation units. The gaseous mixture transported through this line (2" diameter, 30 bar, 40°C) was composed of…

The event occurred during the fuelling process of the primary fuel tank of the core stage of a moon rocket. The initial slow-filling phase was terminated, and personnel had just started the fast…

A hydrogen leak occurred in a CO (carbon monoxide) - hydrogen separation cold box of an acetic acid plant.

The hydrogen leak occurred on a lorry travelling on a motorway. According to Highways England the vehicle was carrying nine cylinders of gas, one of which had a crack and was leaking. The only way to…

Hydrogen as carrier gas was provided to a reactor gas chromatograph by several compressed hydrogen bottles. The bottles emptied rapidly, but the loss of carrier gas could only be detected when the…

The leak occurred at an heat exchanger of the hydro-isomerisation unit of a refinery. Following the observation of a pressure drop between two heat exchangers, controls were carried out on site. A…