Fire on an alkaline electrolyser
A fire broke out on the insulating plastic elements of an alkaline electrolyser in a unit of a chemical plant. The shift saw the smoke from the control room. The first action was to drain the potash into a tank provided for this purpose and to shut down the electrolyser. The on-call electrician interrupted the electricity. The safety technician brought the fire under control in less than 10 minutes using CO2 extinguishers. After approximately six hours, the unit is restarted.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The INITIATING CAUSE of the event was potash leak on the electrolyser block that induced an electric arc between the electric block and the bus bar. This ignition caused a rise in temperature followed by the outbreak of fire.