Skip to main content

Fire on CGH2 trailer (487)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Fire on CGH2 trailer

A compressed hydrogen trailer released accidentally hydrogen which ignited producing a hissing 60 jet flame. It triggered the evacuation of a one-mile stretch. It was estimated that the tanker burned off about 32,000 cubic feet of hydrogen (ca. 75 kg) over a 2. 5-hour period before the flame was extinguished. The tanker contained about 100,000 cubic feet (ca. 230 kg) in 10 separate tubes. Firefighters climbed on the tanker truck during the incident to shut off the other nine tubes so their contents would not burn off as well.
Event Date
May 17, 2003
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
Causes unknown
Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved
Tanker containing 100,000 cubic feet (ca. 230 kg) in 10 separate tube
Storage/Process Medium
Storage/Process Quantity
230
Location Type
Operational Condition
Pre-event Summary
Unknown
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Post-event Summary

1-mile radius evacuation32,000 cubic feet (75 kg) hydrogen lost

Event Nature
Emergency Action
Firefighters climbed on the tanker truck during the incident to shut off the other nine tubes so their contents would not burn off as well.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Release Duration (s)
9000
Release Amount (kg)
75.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
Flame Type
References
References

Source lost