Skip to main content

HIAD Event Initiating System: Hydrogen System Initiating Event


The explosion occurred at a ramjet engine of an aerospace testing centre. In order to carry out an airtight test on the engine, a pressure gauge was connected, the bolts on the hydrogen supply pipe…
An explosion and fire occurred on a reformer at a fertiliser plant. Source of ignition was auto ignition or electric motor.

A runaway chemical reaction happened in a reactor containing methanol and a substance to be hydrogenated. A large quantity of hydrogen was released; a balloon containing a borohydride exploded.…

The explosion occurred while restarting the ammonia reactor. Synthetic gas (70% H2) was released at the flange of the relief valve of the turbo-compressor. The explosion was followed by a jet fire.…

This event occurred at the accelerator bubble chamber facility. During final stages of chmaber cooldown and its loading with LH2 (95% fill, about 95 gallons), an explosion and fire occurred…

During initial resting at a liquid hydrogen bubble chamber facility, an explosion occurred shortly after opening a high pressure hydroger line. The explosion was assumed to have taken place in the…

The incident affected the raw material buffer tank (design pressure 0. 38 MPa) of a diesel hydrogenation unit in a refinery. This buffer tank is located between the hydrogenation reactor and the raw…
The event occurred at one of the unit producing iron powder, consisting of a furnace with a running belt for the powder, kept under hydrogen atmosphere to reduce and purify the metal. The hydrogen…
An explosion and a fire occurred at at a hydro-treatment unit of a chemical plant for lubricants. Plant own emergency response team was activated, assisted from local fire and emergency Services and…
The incident occurred at the hydro-dealkylation (HDA) plant of an aromatics manufacturer. The affected component was a heat exchanger part of the hydrogen purification system. This part failed…
The explosion occurred in the compressors unit of the plant. Witnesses reported a cloud of yellow smoke and a fire ball at its bottom. This first event was followed by a fire fed by a hydrogen pipe…
A syngas leak (hydrogen + methane) occurred at exit of the ammonia production reactor and led to an explosion followed by a fire. The start point of the sequence of events was the syngas at the…
The incident occurred in a hydrocracker unit of the refinery. A control valve on the liquid line between the high- and the low-pressure separators was erroneously opened and the liquid allowed to…
The explosion occurred in a benzene production unit (Litol process), which was being restarted following a scheduled shutdown for maintenance. About 30 kilograms of hydrogen gas were relesed into a…
The incident at a bio-fuels research laboratory occurred when a visiting research fellow was transferring hydrogen, oxygen and carbon dioxide from compressed gas cylinders into a low-pressure mixing…
SUMMARY The explosion occurred in a catalyst regenerator of the catalytic cracking unit in a fluidized bed during a technical shutdown. A few seconds later, a second explosion is perceived, it is the…
In a chlorine electrolysis facility, a mixture of oxygen and hydrogen in one of the electrolyser cells a short-circuit ignited causing a deflagration. The cover of the cell was a thin plastic film…
An explosion occurred at a chlorine production plant during the restart of the installation. An hydraulic syphon had probably been blocked by fire extinguishing products following a previous fire on…

The incident occurred at a dispenser of a hydrogen refuelling station (HRS). The HRS employee had just terminated the filling of a fuel cell vehicle (FHV) and was depressurising the filling hose,…

An explosion involving hydrogen occurred at cooking oils and other food products plant. It was located at the hydrogen storage tank and caused one injury and two fatalities. The area directly…