Skip to main content

Explosion (594)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion

The explosion occurred at a ramjet engine of an aerospace testing centre. In order to carry out an airtight test on the engine, a pressure gauge was connected, the bolts on the hydrogen supply pipe flange removed and a closing plate inserted. After the successful tightness test, the closing plate was removed and the connection between the hydrogen supply and the engine was restored. A preliminary ramjet engine combustion test was started with air, oxygen, and hydrogen. However, the bolts had been wrongly tightened with an O-ring protruding from the groove on the flange and the pressure gauge main valve had not been not properly closed. This caused a hydrogen gas leak followed by an explosion occurred when the combustion test was ignited.
Event Date
May 11, 1995
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was a hydrogen leak due to wrong installation of the connections The ROOT CAUSE could have been a human error and/or lack of proper instructions/procedures

Facility Information
Application Type
Application
Aerospace
Specific Application Supply Chain Stage
Components Involved
aerospace engines testing laboratory
Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

Atightness test had been performed before the start of engine test. This required the de-installation and re-installation of hydrogen supply connections. From WIKIPEDIA: a ramjet is "a form of airbreathing jet engine that requires forward motion of the engine to provide air for combustion. Ramjets work most efficiently at supersonic speeds around Mach 3 "

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Post-event Summary

The test facilities were destroyed

Event Nature
Release Type
Release Substance
H2, O2, N2 (jet engines fuel)
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association): https://www. khk. or. jp/public_information/incident_investigation/hpg_incident/incident_db. html (accessed May 2025)

The first entry in HIAD was coming from RISCAD, which is now closed.