an explosion occurred in a hydrogen storage tank at the hydrogen station of the oxygen plant of the energy centre. The 10 m3 hydrogen storage tank at the hydrogen station belonging to the oxygen…
A hydrogen-air explosion occurred outside a hydrogen compressor. Gaseous hydrogen was released from the vent stack due to a premature activation of a relief valve. The flammable atmosphere ignited…
A hydrogen compressor had been shut down for repairs and was being put back into service when the explosion occurred, causing damage . The compressor was equipped with interchangeable in take and…
A common vent system was used to connect vent lines from liquid hydrogen storage vessels to the vent stack (which was lit flaring the gas). Low order detonations were observed around the vent…
A steel hydrogen pipeline failed with a circumferential rupture, at a location where a leak had been already detected and repaired. The leak was discovered during a one-call response for planned…
Hydrogen fire in the compressor-turbine chamber of a power plant. The hydrogen leaked from the generator terminal bushing into unventilated terminal segregated bulbar ducting (this is a duct used…
The event occurred at a plant for the production of ethylene, and affected the unit for the hydrogenation of pyrolysis gasoline. During a shutdown operation of the hydrogenation plant, the…
The incident occurred at the site of a gas production company. During the filling of a compressed hydrogen trailer, an end plug thermal pressure relief device (TPRD) had an unplanned activation.…
During startup of the hydrodesulphurisation unit, diesel and hydrogen leaked from a flange near the heat exchanger. The flammable mixture ignited spontaneously, causing a fire. Plant personnel…
The hydrogen fire occurred at a solvent manufacturing plant. Hydrogen leaked from a flange of a hydrogen supply pipe and ignited inside the thermal insulation around the pipe. This first fire was…
This incident occurred at a reactor at a succinic acid manufacturing plant. The reactor was had just terminated the hydro-generation of maleic anhydride for manufacturing succinic acid. Hydrogen…
A vehicle (non-further specified) carrying two hydrogen gas cylinders had to brake suddenly. The two cylinders tipped over, damaging the valve and causing hydrogen gas to leak out and ignite. The…