Skip to main content

Explosion of a chemicals storage tank (815)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion of a chemicals storage tank

In a chemical plant, a 1750 m³ tank containing an ammoniac solution exploded. The anchorage of the tank was ripped, the tank lifted on one side and crashed against the retention wall, which was partially destroyed. 1000 m³ of solution (10-20% NH3) was discharged; the stream destroyed another part of the retaining wall at the opposite side and contaminated the surroundings. The presence of an explosive atmosphere consisting of an air-NH3 / H2 / CH4 mixture was strongly suspected. The source of ignition was unknown (electrostatic, pyrophoric sulphides?). Four people were slightly intoxicated (inhalations). Preventive measures were adopted (inerting, grounding, etc. ).
Event Date
January 3, 1973
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause is the formation and ignition of an flammable atmosphere, probably a mixture consisting of air-NH3 / H2 / CH4. The source of ignition is unknown (electrostatic, pyrophoric sulphides?) ROOT CAUSE analysis is no given.
Facility Information
Application Type
Application
Ammonia production
Specific Application Supply Chain Stage
Components Involved
tank containing an ammoniac solution
Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
4
Number of Fatalities
0
Post-event Summary

4 people were slightly intoxicated (inhalations).

Event Nature
Release Type
Release Substance
NH3 H2 CH4
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

ARIA data base https://www. aria. developpement-durable. gouv. fr/accident/5347/